Aim: This study was to evaluate the applicability of Doppler velocimetry to determine its correlation with fetal outcome in dichorionic twin pregnancies. Material and methods: Doppler examination of the umbilical artery (UA) and middle cerebral artery (MCA) was performed in 57 twin pairs. Abnormal values of the umbilical artery pulsatility index (PI), umbilical artery Resistive index (RI) were above the 95th percentile and below 5th percentile for the Middle cerebral artery pulsatility index (MCA PI) and Middle cerebral artery resistivity index (MCA RI) for gestational week. The difference of UA PI ≥0.5 in twin pairs was considered abnormal. Results: 33 subjects had a fetal discordance of greater than 15%. Birth weight was found to be significantly lower in subjects with Umbilical artery PI greater than 95 th percentile for gestational age (p=0.014). Abnormal MCA RI (P=0.018) and Umbilical artery RI values above 95 th percentile was significantly associated with increased risk of IUGR (intra uterine growth restriction) (P=0.036) and NICU (Neonatal intensive care unit) admission (P=0.005). Increased Umbilical artery PI values above 95 th percentile was significantly associated with IUGR (P=0.003). Increased Umbilical Artery systolic/diastolic ratio above 95 th percentile was significantly associated with IUGR (P=0.002), NICU admission (P=0.026) and still birth (P=0.026). Abnormal cerebra-umbilical ratio (<1.08) was significantly associated with IUGR (P=0.001) and still birth (P=0.025). Difference in pulsatility index of umbilical artery of both fetus (P1-P2 >0.5) was significantly correlated with increased degree of birth weight discordance of the twins, IUGR (P=0.001) and still birth (P=0.001). Conclusion: Abnormal Doppler values in discordant twin fetus are more likely to be associated with abnormal fetal outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.