Summary. Background: The life expectancy of non-severe hemophilia A (HA) patients equals the life expectancy of the non-hemophilic population. However, data on the effect of inhibitor development on mortality and on hemophilia-related causes of death are scarce. The development of neutralizing factor VIII antibodies in non-severe HA patients may dramatically change their clinical outcome due to severe bleeding complications. Objectives: We assessed the association between the occurrence of inhibitors and mortality in patients with non-severe HA. Methods: In this retrospective cohort study, clinical data and vital status were collected for 2709 non-severe HA patients (107 with inhibitors) who were treated between 1980 and 2011 in 34 European and Australian centers. Mortality rates for patients with and without inhibitors were compared. Results: During 64 200 patient-years of follow-up, 148 patients died (mortality rate, 2.30 per 1000 person-years; 95% confidence interval (CI), 1.96-2.70) at a median age of 64 years (interquartile range [IQR], 49-76). In 62 patients (42%) the cause of death was hemophilia related. Sixteen inhibitor patients died at a median age of 71 years (IQR,. In ten patients the inhibitor was present at time of death; seven of them died of severe bleeding complications. The all-cause mortality rate in inhibitor patients was > 5 times increased compared with that for those without inhibitors (ageadjusted mortality rate ratio, 5.6). Conclusion: Inhibitor development in non-severe hemophilia is associated with increased mortality. High rates of hemophilia-related mortality in this study indicate that non-severe hemophilia is not mild at all and stress the importance of close follow-up for these patients.
Desmopressin increases endogenous factor VIII levels in hemophilia A. Large inter-individual variation in the response to desmopressin is observed. Patients with a lower baseline factor VIII activity tend to show a reduced response, therefore, desmopressin is less frequently used in moderate hemophilia A patients (baseline factor VIII activity 1-5 international units/deciliter), even though factor VIII levels may rise substantially in some of them. We aim to describe the response to desmopressin in moderate hemophilia A patients and to identify predictors. We selected data on 169 patients with moderate hemophilia from the multicenter Response to DDAVP In non-severe hemophilia A patients: in Search for dEterminants (RISE) cohort study. Adequate response to desmopressin was defined as a peak factor VIII level ≥ 30, and excellent response as ≥ 50 international units/deciliter after desmopressin administration. We used univariate and multiple linear regression techniques to analyze predictors of the peak factor VIII level. Response was considered adequate in 68 patients (40%), of whom 25 showed excellent response (15%). Intravenous administration, age, pre-desmopressin factor VIII activity and von Willebrand factor antigen, peak von Willebrand factor activity and desmopressin-induced rise in von Willebrand factor antigen were significant predictors of peak factor VIII level and explained 65% of the inter-individual variation. In 40% of moderate hemophilia A patients, desmopressin response was adequate, thus it is important not to with-hold this group of patients from desmopressin responsiveness. Among the six predictors that we identified for desmopressin-induced factor VIII rise, factor VIII activity and desmopressin-induced rise in von Willebrand factor antigen had the strongest effect.
Background Non-severe hemophilia (factor VIII concentration [FVIII:C] of 2-40 IU dL ) is characterized by a milder bleeding phenotype than severe hemophilia A. However, some patients with non-severe hemophilia A suffer from severe bleeding complications that may result in death. Data on bleeding-related causes of death, such as fatal intracranial bleeding, in non-severe patients are scarce. Such data may provide new insights into areas of care that can be improved. Aims To describe mortality rates, risk factors and comorbidities associated with fatal intracranial bleeding in non-severe hemophilia A patients. Methods We analyzed data from the INSIGHT study, an international cohort study of all non-severe hemophilia A patients treated with FVIII concentrates during the observation period between 1980 and 2010 in 34 participating centers across Europe and Australia. Clinical data and vital status were collected from 2709 patients. We report the standardized mortality rate for patients who suffered from fatal intracranial bleeding, using a general European male population as a control population. Results Twelve per cent of the 148 deceased patients in our cohort of 2709 patients died from intracranial bleeding. The mortality rate between 1996 and 2010 for all ages was 3.5-fold higher than that in the general population (95% confidence interval [CI] 2.0-5.8). Patients who died from intracranial bleeding mostly presented with mild hemophilia without clear comorbidities. Conclusion Non-severe hemophilia A patients have an increased risk of dying from intracranial bleeding in comparison with the general population. This demonstrates the need for specialized care for non-severe hemophilia A patients.
To cite this article: Loomans JI, van Velzen AS, Eckhardt CL, Peters M, M€ akipernaa A, Holmstrom M, Brons PP, Dors N, Haya S, Voorberg J, van der Bom JG, Fijnvandraat K. Variation in baseline factor VIII concentration in a retrospective cohort of mild/moderate hemophilia A patients carrying identical F8 mutations. J Thromb Haemost 2017; 15: 246-54. Essentials• Factor VIII levels vary in mild and moderate hemophilia A (MHA) patients with the same mutation.• We aimed to estimate the variation and determinants of factor VIII levels among MHA patients.• Age and genotype explain 59% of the observed interindividual variation in factor VIII levels.• Intra-individual variation accounted for 45% of the variation in the three largest mutation groups.Summary. Background: The bleeding phenotype in patients with mild/moderate hemophilia A (MHA) is inversely associated with the residual plasma concentration of factor VIII (FVIII:C). Within a group of patients with the same F8 missense mutation, baseline FVIII:C may vary, because, in healthy individuals, von Willebrand factor (VWF) levels, ABO blood group and age are also known to influence baseline FVIII:C. Our understanding of the pathophysiologic process of the causative genetic event leading to reduced baseline FVIII:C in MHA patients is still limited. Objectives: To estimate the variation and determinants of baseline FVIII:C among MHA patients with the same F8 missense mutation. Methods: Three hundred and forty-six patients carrying mutations that were present in at least 10 patients in the cohort were selected from the INSIGHT and the RISE studies, which are cohort studies including data of 3534 MHA patients from Europe, Canada, and Australia. Baseline FVIII:C was measured with a one-stage clotting assay. We used Levene's test, univariate and multivariate linear regression, and mixed-model analyses. Results: For 59% of patients, the observed variation in baseline FVIII: C was explained by age and genotype. Compared to FVIII:C in patients with Arg612Cys, FVIII:C was significantly different in patients with eight other F8 missense mutations. Intra-individual variation explained 45% of the observed variance in baseline FVIII:C among patients with the same mutation. Conclusion: Our results indicate that baseline FVIII:C levels are not exclusively determined by F8 genotype in MHA patients. Insights into other factors may provide potential novel targets for the treatment of MHA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.