The aim of this investigation was to determine the motility patterns of inflammatory and fibrostenotic phenotypes of eosinophilic esophagitis (EoE) utilizing high-resolution manometry (HRM). Twenty-nine patients with a confirmed diagnosis of EoE according to clinicopathological criteria currently being managed at the Joy McCann Culverhouse Swallowing Center at the University of South Florida were included in the retrospective analysis. Only patients who completed HRM studies were included in the analysis. Patients were classified into inflammatory or fibrostenotic subtypes based on baseline endoscopic evidence. Their baseline HRM studies prior to therapy were analyzed. Manometric data including distal contractile integral, integrated relaxation pressure, and intrabolus pressure (IBP) values were recorded. HRM results were interpreted according to the Chicago Classification system. Statistical analysis was performed with SPSS software (Version 22, IBM Co., Armonk, NY, USA). Data were compared utilizing Student's t-test, χ(2) test, Pearson correlation, and Spearman correlation tests. Statistical significance was set at P < 0.05. A total of 29 patients with EoE were included into the retrospective analysis. The overall average age among patients was 40 years. Male patients comprised 62% of the overall population. Both groups were similar in age, gender, and overall clinical presentation. Seventeen patients (58%) had fibrostenotic disease, and 12 (42%) displayed inflammatory disease. The average IBP for the fibrostenotic and inflammatory groups were 18.6 ± 6.0 mmHg and 12.6 ± 3.5 mmHg, respectively (P < 0.05). Strictures were only seen in the fibrostenotic group. Of the fibrostenotic group, 6 (35%) demonstrated proximal esophageal strictures, 7 (41%) had distal strictures, 3 (18%) had mid-esophageal strictures, and 1 (6%) patient had pan-esophageal strictures. There was no statistically significant correlation between the level of esophageal stricture and degree of IBP. Integrated relaxation pressure, distal contractile integral, and other HRM metrics did not demonstrate statistical significance between the two subtypes. There also appeared no statistically significant correlation between patient demographics and esophageal metrics. Patients with the fibrostenotic phenotype of EoE demonstrated an IBP that was significantly higher than that of the inflammatory group.
Eosinophilic esophagitis is characterized by dysphagia with esophageal eosinophilia. We sought to determine if intrabolus pressure measurements on high-resolution manometry had any correlation with dysphagia improvement following standard therapy for patients with fibrostenotic eosinophilic esophagitis. Consecutive patients were prospectively enrolled at our swallowing center. Dysphagia scores, esophageal eosinophil counts, endoscopic reference scores, and intrabolus pressure measurements were compared at baseline and following therapy with 8 weeks of a proton-pump inhibitor and serial bougie dilation to a luminal diameter of 17 mm. Five patients were included in the study. The median age was 38 years. The average endoscopic reference score improved from 5.0 to 2.4 (p = 0.007). The mean esophageal diameter improved from 10.8 mm to 17.2 mm (p = 0.001). Dysphagia severity scores improved from a mean value of 34.2 to 10.8 (p = 0.004). Mucosal eosinophilia had no correlation with dysphagia severity. Mean intrabolus pressure improved from 21.8 mmHg to 11 mmHg (p = 0.001). There was strong correlation between a decrease in intrabolus pressure and improvement in dysphagia severity; however, this was not significant (p = 0.108). Intrabolus pressure has strong correlation with dysphagia severity following therapy for fibrostenotic eosinophilic esophagitis. Bougie dilation provides improvement in dysphagia despite persistent mucosal eosinophilia.
Figure 1. Statistical analysis of Chronic Liver Disease patients and Weight LossTable 1. Demographics Patients, n 24 Men, n (%) 9 (37.5%) Women, n (%) 15 (62.5%) Age, mean in years (std dev) 53 (1/-12.05) Hyperlipidemia, n (%) 17 (70.83%) HTN, n (%) 16 (66.67%) EtOH users, n (%) 13 (54.17%) Stage 0-2 fibrosis, n (%) 6 (25%) Stage 3 Fibrosis, n (%) 3 (12.5%) Stage 4 Fibrosis, n (%) 15 (62.5%) BMI on Fibroscan, mean (std dev) 35.7 (1/-9.9) BMI on Liver Biopsy, mean (std dev) 34.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.