Background The effectiveness of Gamma Knife radiosurgery (GKR) for cerebral arteriovenous malformations (AVM) is predicated on inclusion of the entire nidus while excluding normal tissue. As such, GKR may be limited by the resolution and accuracy of the imaging modality used in targeting. Objective We present the first case series to demonstrate the feasibility of utilizing ultra-high-resolution C-arm cone beam computed tomography angiography (CBCT-A) in AVM targeting. Methods From June 2009 to June 2013, CBCT-A was utilized for targeting of all patients with AVMs treated with GKR at our institution. Patients underwent Leksell stereotactic head frame placement followed by catheter-based biplane 2-D digital subtraction angiography (DSA), 3-D rotational angiography (3DRA), as well as CBCT-A. The CBCT-A dataset was used for stereotactic planning for GKR. Patients were followed up at 1, 3, 6, and 12 months, and then annually thereafter. Results CBCT-A-based targeting was used in twenty-two consecutive patients. CBCT-A provided detailed spatial resolution and sensitivity of nidal angioarchitecture enabling treatment. The average radiation dose to the margin of the AVM nidus corresponding to the 50% percent isodose line was 15.6 Gy. No patient had treatment-associated hemorrhage. At early follow-up (mean=16 months), 84% of patients had a decreasing or obliterated AVM nidus. Conclusion CBCT-A-guided radiosurgery is feasible and useful because it provides sufficient detailed resolution and sensitivity for imaging brain AVMs.
Object. Intracranial atherosclerotic disease (ICAD) carries a high risk of stroke. Evaluation of ICAD has focused on assessing the absolute degree of stenosis, although plaque morphology has recently demonstrated increasing relevance. The authors provide the first report of the use of ultra-high-resolution C-arm cone-beam CT angiography (CBCT-A) in the evaluation of vessel stenosis as well as plaque morphology.Methods. Between August 2009 and July 2012, CBCT-A was used in all patients with ICAD who underwent catheter-based angiography at the authors' institution (n = 18). Lesions were evaluated for maximum degree of stenosis as well as plaque morphological characteristics (ulcerated, calcified, dissected, or spiculated) via digital subtraction angiography (DSA), 3D-rotational angiography (3DRA), and CBCT-A. The different imaging modalities were compared in their assessment of absolute stenosis as well as their ability to resolve different plaque morphologies.Results. Lesions were found to have similar degrees of stenosis when utilizing CBCT-A compared with 3DRA, but both 3DRA and CBCT-A differed from DSA in their assessment of the absolute degree of stenosis. CBCT-A provided the most detailed resolution of plaque morphology, identifying a new plaque characteristic in 61% of patients (n = 11) when compared with DSA and 50% (n = 9) when compared with 3DRA. CBCT-A identified all lesion characteristics visualized on DSA and 3DRA.Conclusions. CBCT-A provides detailed spatial resolution of plaque morphology and may add to DSA and 3DRA in the evaluation of ICAD. Further prospective study is warranted to determine any benefit CBCTA-A may provide in clinical decision making and risk stratification over existing conventional imaging modalities. This article contains some figures that are displayed in color on line but in black-and-white in the print edition. M. G. Safain et al. 442J Neurosurg / Volume 121 / August 2014 cranial stent placement during aneurysm treatment, 20,22 and delineate cerebral 15,16 and spinal arteriovenous malformations.1 Furthermore, CBCT-A has since been shown to have excellent spatial resolution of the intracranial vasculature, including the ability to resolve submillimeter objects such as stent struts measuring 50-70 µm. 13Despite these uses of CBCT-A in evaluation of intracranial vessels, its utility in determining stenosis and plaque morphology in ICAD has not been previously evaluated.Given the high spatial resolution provided by CBCT-A, we have, since August 2009, obtained imaging studies in all patients undergoing catheter-based angiography for ICAD using this modality, in addition to contemporaneous standard DSA and 3DRA. We sought here to compare and quantify the resolution of CBCT-A compared with 3DRA as well as DSA in the evaluation of ICAD. We present the initial report of additional plaque characteristics identified by CBCT-A in patients with ICAD. Methods Case SelectionDuring the study time period of August 2009 to July 2012, all patients undergoing catheter-based angiography for the ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.