Patients with obstructive coronary artery disease (CAD) undergoing orthotopic liver transplantation (OLT) are at increased risk of poor outcomes. The accuracy of dobutamine stress echocardiography (DSE) to detect obstructive CAD is not well established in this population. We retrospectively identified patients with end-stage liver disease who underwent both DSE and coronary angiography as part of risk stratification prior to OLT. One hundred and five patients had both DSE and angiography, of whom 14 had known CAD and 27 failed to reach target heart rate during DSE. Among the remaining 64 patients (45 men; average age 61 ± 8 years) DSE had a low sensitivity (13%), high specificity (85%), low positive predictive value (PPV) (22%) and intermediate negative predictive value (NPV) (75%) for obstructive CAD. DSE as a screening test for obstructive CAD in OLT candidates has a poor sensitivity. The frequent chronotropic incompetence and low sensitivity in patients who achieve target heart rate, even in those with multiple cardiovascular disease risk factors, suggest that alternative or additional methods of risk stratification are necessary.
Introduction: Common manifestations of multiple myeloma include osteolytic lesions, cytopenias, hypercalcemia, and renal insufficiency. Patients may also exhibit heart failure which is often associated with either past therapy or cardiac amyloidosis. A less recognized mechanism is high-output heart failure. Diuretic therapy in this setting has little efficacy in treating the congested state. Furthermore, effective pharmacotherapy has not been established. We report two patients with multiple myeloma and highoutput heart failure who failed diuretic therapy. The patients were given dexamethasone in conjunction with lenalidomide and thalidomide, respectively. Shortly thereafter, each patient demonstrated a significant improvement in symptoms. This is the first report of successful treatment of multiple myeloma-induced high-output failure via the utilization of these agents.
Previous studies have used standard B-mode ultrasound to quantify the aggregate mean intimal medial thickness (IMT) of the near and far wall of the common carotid artery (CCA). Many investigators have had dif culty in accurately evaluating the near wall IMT secondary to dif culty in discerning the vessel lumen and intima. The purpose of this study is to determine the effect of contrast enhanced ultrasound on IMT measurement when compared with non-enhanced images. Twenty-six patients who had standard carotid ultrasounds completed over a 6-month period were evaluated, with 24 imaged by the same sonographer. Five to six measurements of the near and far walls were obtained over a 1 cm distance, beginning and ending 0.5 cm and 1.5 cm proximal to the carotid bifurcation. The measurements were made with and without the contrast agent Optison T M (per utren protein type-A microspheres), which was given as an IV bolus (0.5¡0.7 cc). Of those imaged by the same sonographer, 40 carotid arteries were examined and a total of 867 measurements were obtained. A total of 10% of the carotid ultrasounds were restudied approximately 1 month after the initial interpretation to assess observer accuracy. The near wall CCA mean (
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.