Optoacoustic imaging, based on the differences in optical contrast of blood hemoglobin and oxyhemoglobin, is uniquely suited for the detection of breast vasculature and tumor microvasculature with the inherent capability to differentiate hypoxic from the normally oxygenated tissue. We describe technological details of the clinical ultrasound (US) system with optoacoustic (OA) imaging capabilities developed specifically for diagnostic imaging of breast cancer. The combined OA/US system provides co-registered and fused images of breast morphology based upon gray scale US with the functional parameters of total hemoglobin and blood oxygen saturation in the tumor angiogenesis related microvasculature based upon OA images. The system component that enabled clinical utility of functional OA imaging is the hand-held probe that utilizes a linear array of ultrasonic transducers sensitive within an ultrawide-band of acoustic frequencies from 0.1 MHz to 12 MHz when loaded to the high-impedance input of the low-noise analog preamplifier. The fiberoptic light delivery system integrated into a dual modality probe through a patented design allowed acquisition of OA images while minimizing typical artefacts associated with pulsed laser illumination of skin and the probe components in the US detection path. We report technical advances of the OA/US imaging system that enabled its demonstrated clinical viability. The prototype system performance was validated in well-defined tissue phantoms. Then a commercial prototype system named Imagio™ was produced and tested in a multicenter clinical trial termed PIONEER. We present examples of clinical images which demonstrate that the spatio-temporal co-registration of functional and anatomical images permit radiological assessment of the vascular pattern around tumors, microvascular density of tumors as well as the relative values of the total hemoglobin [tHb] and blood oxygen saturation [sO2] in tumors relative to adjacent normal breast tissues. The co-registration technology enables increased accuracy of radiologist assessment of malignancy by confirming, upgrading and/or downgrading US categorization of breast tumors according to Breast Imaging Reporting And Data System (BI-RADS). Microscopic histologic examinations on the biopsied tissue of the imaged tumors served as a gold standard in verifying the functional and anatomic interpretations of the OA/US image feature analysis.
In ultrasound imaging, fully-developed speckle arises from the spatiotemporal superposition of pressure waves backscattered by randomly distributed scatterers. Speckle appearance is affected by the imaging system characteristics (lateral and axial resolution) and the random-like nature of the underlying tissue structure. In this work, we examine speckle formation in acoustic-resolution photoacoustic (PA) imaging using simulations and experiments. Numerical and physical phantoms were constructed to demonstrate that PA speckle carries information related to unresolved absorber structure in a manner similar to ultrasound speckle and unresolved scattering structures. A fractal-based model of the tumor vasculature was used to study PA speckle from unresolved cylindrical vessels. We show that speckle characteristics and the frequency content of PA signals can be used to monitor changes in average vessel size, linked to tumor growth. Experimental validation on murine tumors demonstrates that PA speckle can be utilized to characterize the unresolved vasculature in acoustic-resolution photoacoustic imaging.
Opto-acoustic imaging involves using light to produce sound waves for visualizing blood in biological tissue. By using multiple optical wavelengths, diagnostic images of blood oxygen saturation and total hemoglobin are generated using endogenous optical contrast, without injection of any external contrast agent and without using any ionizing radiation. The technology has been used in recent clinical studies for diagnosis of breast cancer to help distinguish benign from malignant lesions, potentially reducing the need for biopsy through improved diagnostic imaging accuracy. To enable this application, techniques for mapping oxygen saturation differences within tissue are necessary. Using biologically relevant opto-acoustic phantoms, we analyze the ability of an opto-acoustic imaging system to display colorized parametric maps that are generated using a statistical mapping approach. To mimic breast tissue, a material with closely matching properties for optical absorption, optical scattering, acoustic attenuation, and speed of sound is used. The phantoms include two vessels filled with whole blood at oxygen saturation levels determined using a sensor-based approach. A flow system with gas-mixer and membrane oxygenator adjusts the oxygen saturation of each vessel independently. Datasets are collected with an investigational Imagio ® breast imaging system. We examine the ability to distinguish vessels as the oxygen saturation level and imaging depth are varied. At depth of 15 mm and hematocrit of 42%, a sufficient level of contrast to distinguish between two 1.6-mm diameter vessels was measured for an oxygen saturation difference of ∼4.6%. In addition, an oxygenated vessel was visible at a depth of 48 mm using an optical wavelength of 1064 nm, and a deoxygenated vessel was visible to a depth of 42 mm with 757 nm. The results provide insight toward using color mapped opto-acoustic images for diagnosing breast cancer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.