Center-of-pressure (CoP) displacements play a key role in studies assessing postural stability. The accepted instrument to measure CoP trajectories is the force platform, but pressure-sensitive mats (PSMs) are an alternative composed of a matrix of sensitive cells. A typical cell comprises two electrodes with piezoresistive material in between, while a force platform has a force sensor at each of its corners. In this paper, we compare a homemade Velostat-based PSM and an affordable commercial mat with a commercial force platform in a test series with 42 healthy volunteers in single-legged trials (29 males, 13 females; height 1.74 (0.09) m, weight 74.3 (16.34) kg, age 31.21 (12.66) years). The aim of the research was to perform a preliminary study of the performance of our prototype to measure CoP, and more specifically, the standard deviation of the CoP path on both axes, the medial–lateral and anterior–posterior. We could thus discover several improvements for future clinical applications. The intraclass correlation coefficient (ICC) for agreement in the base experiment showed a moderate value for the prototype (0.38 to 0.63) and lower values for the commercial mat (0.11 to 0.12). However, we identified several factors that were relevant to improve ICC and reduce error by considering several processing options: (i) the known crosstalk problem between cells that appears in this kind of mats must be eliminated; (ii) the response time of the sensor has to be taken into account; and (iii) increasing the mat resolution also improves agreement. Therefore, as future work, we plan to test the improved version of the prototype in a clinical environment.
2-D resistive sensor arrays (RSAs) appear in many applications to measure physical quantities in a surface. However, they suffer from a crosstalk problem when the simplest configuration is used to address a row-column. Thus, the value of a single cell cannot be measured directly. Several hardware solutions have been proposed to solve it totally or partially but all of them make the circuit more complex. In a previous paper we proposed an innovative numerical solution to eliminate crosstalk after a complete scan of the matrix, which is named in this paper as Inverse of Equivalent Conductance Method (IECM). In the current study, we have analyzed the implications of the method for the uncertainty of the calculated cell resistance by first deriving the sensitivity of the solution and then applying uncertainty propagation theory. The theoretical results have been tested in simulated arrays and in a real 6x6 RSA with known values of resistances with good agreement. The uncertainty analysis is able to predict which values are reliable. In general, the lowest resistances of the array are better solved by IECM as expected. In addition, it is also shown that IECM has the potential to be adapted to other hardware configurations that reduce crosstalk, helping to overcome some of its limitations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.