Injection of local anesthetic deep to the brachial plexus sheath at the supraclavicular fossa, under ultrasound-guidance, results in faster onset of surgical anesthesia and prolonged duration of postoperative analgesia than an injection superficial to the sheath.
SummaryPositioning the parturient from supine to the left lateral tilt position (supine-to-tilt) may not effectively displace the gravid uterus, but turning from the left lateral position to the left lateral tilt position (left lateral-to-tilt) may keep the gravid uterus displaced and prevent aortocaval compression. Fifty-one full-term parturients were randomly placed in the left lateral position, supine-to-tilt and left lateral-to-tilt positions using a Crawford wedge. Femoral vein area, femoral vein velocity, femoral artery area, pulsatility index, resistance index and right arm mean arterial blood pressure and heart rate were recorded. Our results showed a lower mean (SD) femoral vein area ( ) and a higher femoral vein velocity (7.9 (1.2) vs 6.1 (1.6) cm.s ) with left lateral-to-tilt when compared with supine-to-tilt (all p < 0.001). Our results suggest that moving a full-term parturient from the full left lateral to the lateral tilt position may prevent aortocaval compression in full-term parturients more efficiently than when positioning the parturient from a supine to left lateral tilt position.
Context:Laryngeal mask airway supreme (LMA-S) has an inflatable cuff while i-gel has a noninflatable cuff made of thermoplastic elastomer.Aims:To study the efficacy of ventilation and the laryngeal seal pressures (LSPs) with either device. Our secondary objectives were to compare the ease of insertion, adequacy of positioning the device, hemodynamic response to device insertion, and any postoperative oropharyngeal morbidity.Settings and Design:A prospective, randomized, single-blinded study at Teaching Medical School in South India.Materials and Methods:Forty-two patients posted for surgery under general anesthesia were randomly divided into two groups - LMA-S and i-gel. After a standardized premedication and anesthesia induction sequence, the supra-glottic devices were introduced. Ease of insertion was assessed from the number of attempts taken to insert, insertion time, and any maneuvers required to insert the device. Position of the device was assessed by the ease of gastric catheter placement and the fibreoptic grading of laryngeal visualization. Efficacy of ventilation was determined from the LSP, peak inspiratory pressure (PIP), and end-tidal carbon dioxide (EtCO2)values. Any postoperative oropharyngeal morbidity was also recorded.Statistical Analysis:Descriptive analysis was reported as a mean and standard deviation, median, and range of continuous variables. Demographics were analyzed using a unpaired t-test for parametric data and Chi-square test for nonparametric data. Respiratory and hemodynamic data was analyzed using one-way ANOVA to find statistical difference within and between the two groups.Results:LMA-S was successfully inserted in 95% of patients and i-gel in 85.5% of patients. There was a significant difference (P = 0.021) in the LSPs between the two groups (18.15 cmH2O in LMA-S and 21.28 cmH2O in the i-gel group). There was no significant difference in the PIPs, leak fraction, and the EtCO2values.Conclusion:Both devices are suitable for positive pressure ventilation (PPV) in anesthetized paralyzed patients. However, i-gel gives a better laryngeal seal when compared to LMA-S and may be chosen preferentially for PPV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.