In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.
Background— The morbidity and mortality of surgical aortic valve replacement are increased in elderly patients with multiple high-risk comorbid conditions. Therefore, a prospective, single-center, nonrandomized study was performed in high-risk patients with aortic valve disease to evaluate the feasibility and safety of percutaneous implantation of a novel self-expanding aortic valve bioprosthesis (CoreValve). Methods and Results— Symptomatic high-risk patients with an aortic valve area <1 cm 2 were considered for enrollment. CoreValve implantation was performed under general anesthesia with extracorporeal support using the retrograde approach. Clinical follow-up and transthoracic echocardiography were performed after the procedure and at days 15 and 30 after device implantation to evaluate short-term patient and device outcomes. A total of 25 patients with symptomatic aortic valve stenosis (mean gradient before implantation, 44.2±10.8 mm Hg) and multiple comorbidities (median logistic EuroScore, 11.0%) were enrolled. Device success and procedural success were achieved in 22 (88%) and 21 (84%) patients, respectively. Successful device implantation resulted in a marked reduction in the aortic valve gradients (mean gradient after implantation, 12.4±3.0 mm Hg; P <0.0001). The mean aortic regurgitation grade was unchanged. Major in-hospital cardiovascular and cerebral events occurred in 8 patients (32%), including mortality in 5 patients (20%). Among 18 patients with device success surviving to discharge, no adverse events occurred within 30 days after leaving the hospital. Conclusions— Percutaneous implantation of the self-expanding CoreValve aortic valve prosthesis in high-risk patients with aortic stenosis with or without aortic regurgitation is feasible and, when successful, results in marked hemodynamic and clinical improvement.
Background— Valve thrombosis has yet to be fully evaluated after transcatheter aortic valve implantation. This study aimed to report the prevalence, timing, and treatment of transcatheter heart valve (THV) thrombosis. Methods and Results— THV thrombosis was defined as follows (1) THV dysfunction secondary to thrombosis diagnosed based on response to anticoagulation therapy, imaging modality or histopathology findings, or (2) mobile mass detected on THV suspicious of thrombus, irrespective of dysfunction and in absence of infection. Between January 2008 and September 2013, 26 (0.61%) THV thromboses were reported out of 4266 patients undergoing transcatheter aortic valve implantation in 12 centers. Of the 26 cases detected, 20 were detected in the Edwards Sapien/Sapien XT cohort and 6 in the Medtronic CoreValve cohort. In patients diagnosed with THV thrombosis, the median time to THV thrombosis post–transcatheter aortic valve implantation was 181 days (interquartile range, 45–313). The most common clinical presentation was exertional dyspnea (n=17; 65%), whereas 8 (31%) patients had no worsening symptoms. Echocardiographic findings included a markedly elevated mean aortic valve pressure gradient (40.5±14.0 mm Hg), presence of thickened leaflets or thrombotic apposition of leaflets in 20 (77%) and a thrombotic mass on the leaflets in the remaining 6 (23%) patients. In 23 (88%) patients, anticoagulation resulted in a significant decrease of the aortic valve pressure gradient within 2 months. Conclusions— THV thrombosis is a rare phenomenon that was detected within the first 2 years after transcatheter aortic valve implantation and usually presented with dyspnea and increased gradients. Anticoagulation seems to have been effective and should be considered even in patients without visible thrombus on echocardiography.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.