A two-step real-time PCR assay targeting all six capsulation loci of Haemophilus influenzae (i.e., serotypes a to f) was developed and compared with a previously published qualitative PCR assay by using 131 H. influenzae clinical isolates. There was a 98.5% concordance between the two tests. The sensitivity of detection of capsular type-specific reference strains of H. influenzae a to c (10 1 CFU/PCR) was higher than that for type e (10 3 CFU/PCR) and types d and f (10 4 CFU/PCR), and a broader dynamic range was obtained (5 to 8 log 10 units). No cross-reaction was observed with bacteria commonly isolated from the respiratory tract. We showed that both PCR assays are more reliable than slide agglutination serotyping. The real-time PCR-based assay seems to be an alternative of choice for the epidemiological follow-up of H. influenzae invasive infections.
In a recent study, Candida species in clinical blood samples were detected using a real-time PCR-based method (Maaroufi et al, J Clin Microbiol 2003, 41:3293-3298). For the present study, we evaluated the efficiency of this method as an adjunct to the BACTEC blood culture system to early detection of positivity and negativity of simulated low candidemias. We first established an in vitro correlation between the inoculum of the most frequently encountered Candida species and the time to positivity of these microorganisms. Then, aliquots from blood culture bottles infected with a final average candidal inoculum of 3.18 colony-forming units (CFU)/culture bottle (range, 1 to 6 CFU) were collected at increasing incubation times, and DNA was extracted and submitted to the TaqMan-based PCR assay. To optimize this assay, we evaluated the effect of adding 0.5% bovine serum albumin (BSA) to DNA extracts and found that it decreased the effects of inhibitors. Using specific probes for the tested Candida species, the PCR assay was positive on blood culture aliquots collected from the BACTEC system after a minimum culture turnaround time (TAT) of 3.11 +/- 1.24 hours. Addition of BSA to PCR reaction mixtures improves the TAT (1.84 +/- 0.41 hours). Hence, the combination of DNA "amplification" in the culture bottles by normal growth with an additional DNA amplification by PCR might be a reliable tool facilitating the early diagnosis of low candidemias.
A major pitfall in most published genomic amplification methods for the detection and identification of human pathogens is that they do not include an internal amplification control in order to achieve an acceptable level of confidence for the absence of false-negative results. By applying composite primer technology, a single multiple internal amplification control DNA molecule was constructed to detect and quantify the hepatitis B virus, human polyomavirus, Epstein-Barr virus, Toxoplasma gondii and cytomegalovirus using real-time PCR. The multiple internal amplification control contains all forward and reverse primer binding regions targeted in the five distinct duplex PCRs, but with a unique probe hybridization site. Multiple internal amplification control detection sensitivity, assessed by Probit analysis, was 58 copies per PCR, associated with an extremely wide dynamic range (8 log 10 units). Moreover, in testing 614 patient samples, PCR inhibition occurred at a frequency of 0-8.8%. Similar multiple internal amplification controls for quantitative PCR-based assays could be designed to accommodate any infectious profiles in a particular institution as they are easy to make and inexpensive.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.