Despite chronic Hepatitis B virus (HBV) infection being the main cause of younger-onset complex liver disease including cirrhosis and hepatocellular carcinoma (HCC) in Africa, very little is known regarding the seroprevalence of HBV in the Gabonese general population. This investigation aimed to provide strong epidemiological data and risk factors associated with HBV infection in first-time blood donors representative of the urban adult population. The screening of HBsAg was carried out using 4th generation ELISA kits. The overall seroprevalence of HBsAg was 7.28%. The frequency of HBsAg was differential and marked by annual variations in blood donors from 2009 to 2016. Seroprevalence was 2-fold higher among males versus females (OR = 1.90 (95% CI: 1.75–2.06), P<0.001). HBsAg seroprevalence was significantly higher in donors of the age group 25–35 years old compared to donors of the age group <18 years (OR = 1.64 (95% CI: 1.03–2.60), P = 0.04). The seroprevalence of HBsAg in family/replacement donors (FRD) was significantly higher than that of voluntary non-remunerated donors (VNRD) (OR = 0.88 (95% CI: 0.83–0.94), P <0.001). The simultaneous comparison of HBsAg seroprevalence with blood donation type, gender and age showed that the higher prevalence in FRD was significant only in males between 18 and 45 years and in females between 25 and 34 years of age. This study confirms the high endemicity of HBV in Gabon while identifying the most infected age groups for both men and women.
Background
Blood transfusion is a pathway for the transmission of blood‐borne pathogens such as human immunodeficiency virus (HIV) and hepatitis B virus (HBV) from donors to recipients in most countries in sub‐Saharan Africa, including Gabon. The study aimed to compare the performance of four rapid diagnostic tests (RDTs: Alere DETERMINE, BIOSYNEX Exacto Pro HIV, MEDIFF HIV 1&2, and BIOSYNEX IMMUNOQUICK HBsAg) with results of 4th‐generation immunoenzymatic assays COBAS 6000 e601 and EVOLIS BioRad for the detection of HIV and hepatitis B surface antigen (HBsAg) in blood donors in Libreville, Gabon.
Methods
Reactive and nonreactive blood samples for HIV and HBsAg were selected using fourth‐generation ELISA COBAS 6000 e601 and EVOLIS BioRad. The sensitivities of RDTs were calculated using Epi Info version 6.04dfr (CDC, Atlanta, USA).
Results
Sensitivities for the detection of HIV in blood donors were 90.9% for Alere DETERMINE, 81.8% for BIOSYNEX Exacto Pro HIV, and 81.8% for MEDIFF HIV 1&2 Serum/sang Total Cassette compared with COBAS 6000 e601. The sensitivity of Alere DETERMINE compared to the semi‐automated ELISA Bio‐Rad for HIV detection was 65.6%. The sensitivity of BIOSYNEX IMMUNOQUICK HBsAg compared to ELISA tests for the detection of HBsAg was 78.0%. The specificity of all RDTs for the detection of HIV and HBsAg was 100%.
Conclusion
Alere DETERMINE HIV‐1/2, MEDIFF HIV 1&2 Serum/sang Total Cassette, BIOSYNEX Exacto Pro HIV, and BIOSYNEX IMMUNOQUICK HBsAg are not recommended for determining whether donors qualify to donate blood because of their low sensitivity for the detection of HIV antibodies and HBsAg in blood donors in Gabon.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.