SummaryBackgroundHigh-sensitivity cardiac troponin assays permit use of lower thresholds for the diagnosis of myocardial infarction, but whether this improves clinical outcomes is unknown. We aimed to determine whether the introduction of a high-sensitivity cardiac troponin I (hs-cTnI) assay with a sex-specific 99th centile diagnostic threshold would reduce subsequent myocardial infarction or cardiovascular death in patients with suspected acute coronary syndrome.MethodsIn this stepped-wedge, cluster-randomised controlled trial across ten secondary or tertiary care hospitals in Scotland, we evaluated the implementation of an hs-cTnI assay in consecutive patients who had been admitted to the hospitals' emergency departments with suspected acute coronary syndrome. Patients were eligible for inclusion if they presented with suspected acute coronary syndrome and had paired cardiac troponin measurements from the standard care and trial assays. During a validation phase of 6–12 months, results from the hs-cTnI assay were concealed from the attending clinician, and a contemporary cardiac troponin I (cTnI) assay was used to guide care. Hospitals were randomly allocated to early (n=5 hospitals) or late (n=5 hospitals) implementation, in which the high-sensitivity assay and sex-specific 99th centile diagnostic threshold was introduced immediately after the 6-month validation phase or was deferred for a further 6 months. Patients reclassified by the high-sensitivity assay were defined as those with an increased hs-cTnI concentration in whom cTnI concentrations were below the diagnostic threshold on the contemporary assay. The primary outcome was subsequent myocardial infarction or death from cardiovascular causes at 1 year after initial presentation. Outcomes were compared in patients reclassified by the high-sensitivity assay before and after its implementation by use of an adjusted generalised linear mixed model. This trial is registered with ClinicalTrials.gov, number NCT01852123.FindingsBetween June 10, 2013, and March 3, 2016, we enrolled 48 282 consecutive patients (61 [SD 17] years, 47% women) of whom 10 360 (21%) patients had cTnI concentrations greater than those of the 99th centile of the normal range of values, who were identified by the contemporary assay or the high-sensitivity assay. The high-sensitivity assay reclassified 1771 (17%) of 10 360 patients with myocardial injury or infarction who were not identified by the contemporary assay. In those reclassified, subsequent myocardial infarction or cardiovascular death within 1 year occurred in 105 (15%) of 720 patients in the validation phase and 131 (12%) of 1051 patients in the implementation phase (adjusted odds ratio for implementation vs validation phase 1·10, 95% CI 0·75 to 1·61; p=0·620).InterpretationUse of a high-sensitivity assay prompted reclassification of 1771 (17%) of 10 360 patients with myocardial injury or infarction, but was not associated with a lower subsequent incidence of myocardial infarction or cardiovascular death at 1 year. Our finding...
In the haemophilic patient, development of antibodies that inhibit the function of the missing coagulation factor causes several delicate problems. Most importantly, antibodies will block the function of the specific coagulation factor, and often the antibody activity is so fierce that effective substitution therapy is outruled. In consequence, alternative measures must be adopted to control bleeding. Amongst those most commonly employed, like factor IX concentrates, activated prothrombin complex concentrates, and factor VIII of porcine origin, a new recombinant activated factor VII molecule has been evaluated clinically for some years with promising results. The aim of the present paper was to present a series of patients suffering from haemophilia A or B in whom inhibitors have complicated the clinical picture, and in whom a surgical procedure was indicated. As part of a compassionate use program devised by the producer of this genetically engineered factor VIla, 12 patients underwent life-saving or essential surgery where the recombinant factor VIla product was used to promote haemostasis in 13 surgical procedures. Due to a short in vivo half-life of activated factor VIla, frequent administration was scheduled, injecting factor VIla every 2-3 h for up to 2 days after which dosage intervals were prolonged. In one case, a global evaluation of the end treatment result was not reported, but in all of the other 12 cases the end result were considered excellent (n = 11) or efficient (n = 1). In none of the cases was other types of coagulation factor treatment modalities necessary. In conclusion, recombinant factor VIla seems a tempting alternative to traditional treatment of the haemophilic patient with inhibitors, in whom surgery is called for. With other types of haemostatic agents, surgery in haemophilic inhibitor patients has only been studied rarely, and operations have generally been restricted to life-threatening situations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.