Fluorescence is widely used for small-volume analysis and is a primary tool for on-chip detection in microfluidic devices, yet additional expertise, more elaborate optics, and phase-locked detectors are needed for ultrasensitive measurements. Recently, we designed a microfluidic analog to an optical beam chopper (μChopper) that alternated formation of picoliter volume sample and reference droplets. Without complex optics, the device negated large signal drifts (1/f noise), allowing absorbance detection in a mere 27 μm optical path. Here, we extend the μChopper concept to fluorescence detection with standard wide-field microscope optics. Precision of droplet control in the μChopper was improved by automation with pneumatic valves, allowing fluorescence measurements to be strictly phase locked at 0.04 Hz bandwidth to droplets generated at 3.50 Hz. A detection limit of 12 pM fluorescein was achieved when sampling 20 droplets, and as few as 310 zeptomoles (3.1 × 10−19 mol) were detectable in single droplets (8.8 nL). When applied to free fatty acid (FFA) uptake in 3T3-L1 adipocytes, this μChopper permitted single-cell FFA uptake rates to be quantified at 3.5 ± 0.2 × 10−15 mol cell−1 for the first time. Additionally, homogeneous immunoassays in droplets exhibited insulin detection limits of 9.3 nM or 190 amol (1.9 × 10−16 mol). The combination of this novel, automated μChopper with lock-in detection provides a high-performance platform for detecting small differences with standard fluorescence optics, particularly in situations where sample volume is limited. The technique should be simple to implement into a variety of other droplet fluidics devices.
In this work, we expand upon our recently developed droplet-based sample chopping concepts by introducing a multiplexed fluidic micro-chopper device (μChopper). Six aqueous input channels were integrated with a single oil input, and each of these seven channels was controlled by a pneumatic valve for automated sampling through software control. This improved design, while maintaining high precision in valve-based droplet generation at bandwidths of 0.03 to 0.05 Hz, enabled a variety of analytical modes to be employed on-chip compared to previous devices limited to sample/reference alternations. The device was analytically validated for real-time, continuous calibration with a single sample and five standards; multiplexed analysis during calibration using a mixed mode; and standard addition through spiking of six sample droplets with varying amounts of standard. Finally, the standard addition mode was applied to protein quantification in human serum samples using on-chip, homogeneous fluorescence immunoassays. Ultimately, with only ~1.2 μL of total analyzed solution volume— representing 100-fold and 75-fold reductions in reagent and serum volumes, respectively—we were able to generate full, six-point standard addition curves in only 1.5 min, and results correlated well with those from standard plate-reader equipment. This work thus exploited microfluidic valves for both their automation and droplet phase-locking capabilities, resulting in a micro-analytical tool capable of complex analytical interrogation modes on sub-microliter sample volumes while also leveraging drastic noise rejection via lock-in detection. The multichannel μChopper device should prove particularly useful in analyzing precious biological samples or for dynamic analyses at small volume scales.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.