Background
The administration of 5-fluorouracil (5FU) in the treatment of gastrointestinal (GI) malignancies is associated with common side effects such as mucositis, diarrhoea, and myelosuppression, which are easily managed with supportive measures and dose adjustments. Cardiotoxicity and neurotoxicity are rare but reversible side effects of 5-FU and are treated with withdrawal of the drug and conservative measures. The presenting symptoms of 5-FU-induced leukoencephalopathy are often confusing and pose a diagnostic dilemma in routine clinical practice.
Methods
We report a series of five patients with GI malignancies who developed 5-FU-induced leukoencephalopathy.
Results
All (n = 5) had Naranjo scores of 6–7, predictive of 5-FU-related adverse effects, with clinical and radiological findings suggestive of 5-FU-induced encephalopathy as described in prior literature. The median time to onset of symptoms from initiation of 5FU was 3 days (range: 2–4 days). All patients improved after conservative management with complete neurological recovery.
Conclusion
Prompt recognition of this rare yet severe adverse effect of 5-FU-based chemotherapy aids early withdrawal of the offending agent (5-FU) and timely initiation of supportive measures and helps plan alternative oncological interventions.
Aim:
To compare dose to target and organs at risk (OARs) in conventional plan (2D) versus computed tomography (CT)-based three-dimensional (3D) plan in vaginal cuff brachytherapy (VBT) and to compare the effect of bladder distension on target and OARs dosimetry.
Materials and methods:
Post-hysterectomy patients with an indication for VBT were included in the study. All patients underwent planning CT scans with a full bladder and an empty bladder protocol. For each CT, two plans were generated—one library-based 2D plan and another CT-based 3D plan. Dosimetric parameters were recorded for clinical target volume (CTV) and OARs.
Results:
A total of 92 observations were made from data collected from 46 patients. Difference between CTV dose in terms of 2D and 3D plans were not statistically significant for CTV (p = 0·11). Significant reduction in D0·1cc, D1cc and D2cc dose parameters were observed in bladder, rectum, sigmoid and bowel doses with the 3D plan (p < 0·001). Bladder distension showed a 20% reduction in dose for bowel (p < 0·001). Bladder distension also showed a 6·12% (p = 0·047) increase in D2cc, but there was a significant reduction in the mean dose to the bladder.
Conclusion:
Our study demonstrates the dosimetric benefits with 3D CT-based planning for VBT over 2D-based conventional planning and benefit of bladder distension in the reduction of bowel dose without compromising dose to the target volume.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.