Accurate temperature predictions are essential to the optimization of gas turbine component design. This paper provides an update on the application of recent developments in heat transfer boundary condition derivation and finite element model validation. Computational fluid dynamics (CFD) is increasingly being used to determine cooling flow distributions and convective heat fluxes on a range of components. Validation of the CFD methodology for internal cavity heat transfer is also a key focus of major research programmes. In this paper, further results are presented for selected engine and rig cavities. A fully coupled CFD/finite element thermal model solution is also demonstrated. Increasingly, the application of optimization techniques to the thermal model calibration process is showing that significant savings in analysis time can be achieved for a given accuracy of ‘match’. The optimization process is described and sample results are presented from the calibration of a typical thermal model. Finally, the impact of these new analysis techniques on the derivation of thermal boundary conditions in gas turbine component cavities and the implications for compliance with Airworthiness Authority regulations are summarized with respect to offering an improved temperature prediction validation strategy.
Optimisation of cooling systems within gas turbine engines is of great interest to engine manufacturers seeking gains in performance, efficiency and component life. The effectiveness of coolant delivery is governed by complex flows within the stator wells and the interaction of main annulus and cooling air in the vicinity of the rim seals. This paper reports the development of a test facility which allows the interaction of cooling air and main gas paths to be measured at conditions representative of those found in modern gas turbine engines. The test facility features a two stage turbine with an overall pressure ratio of approximately 2.6:1. Hot air is supplied to the main annulus using a Rolls-Royce Dart compressor driven by an aero-derivative engine plant. Cooling air can be delivered to the stator wells at multiple locations and at a range of flow rates which cover bulk ingestion through to bulk egress. The facility has been designed with adaptable geometry to enable rapid changes of cooling air path configuration. The coolant delivery system allows swift and accurate changes to the flow settings such that thermal transients may be performed. Particular attention has been focused on obtaining high accuracy data, using a radio telemetry system, as well as thorough through-calibration practices. Temperature measurements can now be made on both rotating and stationary discs with a long term uncertainty in the region of 0.3 K. A gas concentration measurement system has also been developed to obtain direct measurement of re-ingestion and rim seal exchange flows. High resolution displacement sensors have been installed in order to measure hot running geometry. This paper documents the commissioning of a test facility which is unique in terms of rapid configuration changes, non-dimensional engine matching and the instrumentation density and resolution. Example data for each of the measurement systems is presented. This includes the effect of coolant flow rate on the metal temperatures within the upstream cavity of the turbine stator well, the axial displacement of the rotor assembly during a commissioning test, and the effect of coolant flow rate on mixing in the downstream cavity of the stator well.
Market competitiveness for aero engine power plant dictates that improvements in engine performance and reliability are guaranteed a priori by manufacturers. The requirement to accurately predict the life of engine components makes exacting demands of the internal air system, which must provide effective cooling over the engine duty cycle with the minimum consumption of compressor section air. Tests have been conducted at the University of Sussex using a turbine test facility which comprises a two stage turbine with an individual stage pressure ratio of 1.7:1. Main annulus air is supplied by an adapted Rolls-Royce Dart compressor at up to 440 K and 4.8 kg s−1. Cooling flow rates ranging from 0.71 to 1.46 Cw, ent, a disc entrainment parameter, have been used to allow ingress or egress dominated stator well flow conditions. The mechanical design of the test section allows internal cooling geometry to be rapidly re-configured, allowing the effect of jet momentum and coolant trajectory to be investigated. An important facet to this investigation is the use of CFD to model and analyse the flow structures associated with the cavity conditions tested, as well as to inform the design of cooling path geometry. This paper reports on the effectiveness of stator well coolant flow rate and delivery configurations using experimental data and also CFD analysis to better quantify the effect of stator well flow distribution on component temperatures.
Reliable means of predicting heat transfer in cavities adjacent to the main gas path are increasingly being sought by engineers involved in the design of gas turbines. In this paper, an interim summary of the results of a five-year research program sponsored by the European Union (EU) and several leading gas turbine manufacturers and universities will be presented. Extensive use is made of computational fluid dynamics (CFD) and finite element (FE) modeling techniques to understand the thermo-mechanical behavior of a turbine stator well cavity, including the interaction of cooling air supply with the main annulus gas. The objective of the study has been to provide a means of optimizing the design of such cavities for maintaining a safe environment for critical parts, such as disc rims and blade fixings, while maximizing the turbine efficiency and minimizing the fuel burn and emissions penalties associated with the secondary airflow system. The modeling methods employed have been validated against data gathered from a dedicated two-stage turbine rig running at engine representative conditions. Extensive measurements are available for a range of flow conditions and alternative cooling arrangements. The analysis method has been used to inform a design change, which is also to be tested. Comparisons are provided between the predictions and measurements of the turbine stator well component temperature.
This paper summarizes the work of a five year research program into the heat transfer within cavities adjacent to the main annulus of a gas turbine. The work has been a collaboration between several gas turbine manufacturers, also involving a number of universities working together. The principal objective of the study has been to develop and validate computer modeling methods of the cooling flow distribution and heat transfer management, in the environs of multistage turbine disk rims and blade fixings, with a view to maintaining component and subsystem integrity, while achieving optimum engine performance and minimizing emissions. A fully coupled analysis capability has been developed using combinations of commercially available and in-house computational fluid dynamics (CFD) and finite element (FE) thermomechanical modeling codes. The main objective of the methodology is to help decide on optimum cooling configurations for disk temperature, stress, and life considerations. The new capability also gives us an effective means of validating the method by direct use of disk temperature measurements, where otherwise, additional and difficult to obtain parameters, such as reliable heat flux measurements, would be considered necessary for validation of the use of CFD for convective heat transfer. A two-stage turbine test rig has been developed and improved to provide good quality thermal boundary condition data with which to validate the analysis methods. A cooling flow optimization study has also been performed to support a redesign of the turbine stator well cavity to maximize the effectiveness of cooling air supplied to the disk rim region. The benefits of this design change have also been demonstrated on the rig. A brief description of the test rig facility will be provided together with some insights into the successful completion of the test program. Comparisons will be provided of disk rim cooling performance for a range of cooling flows and geometry configurations. The new elements of this work are the presentation of additional test data and validation of the automatically coupled analysis method applied to a partially cooled stator well cavity (i.e., including some local gas ingestion) and also the extension of the cavity cooling design optimization study to other new geometries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.