BackgroundImaging protocols are implemented to identify and minimise set-up errors. A crucial component to the success of these protocols is staff compliance.Materials and methodsThis is case report describing a retrospective review of radiation therapists’ compliance to a palliative imaging protocol in a single large institution in one calendar year.ResultsThe review showed a non-compliance to protocol for 8% of treatments. The most frequent protocol deviation was a failure to calculate the mean set-up displacement after 2/3 days of consecutive imaging.ConclusionDespite the presence of institutional evidence-based palliative imaging protocol unwanted deviations in practice can occur.
Background: Accuracy and reproducibility of the patient’s position is crucial for successful delivery of radiotherapy (RT). Data on palliative patients’ set-up uncertainties are sparse. The aim of this study was to calculate set-up errors observed for palliative patients positioned using one skin mark (Group 1) versus three skin marks (Group 2) and to assess the accuracy of both approaches. Methods: Displacements in the left–right (L–R) and superior–inferior (S–I) directions were retrospectively analysed for 175 sites treated with a course of fractionated palliative RT. Population mean, systematic and random errors were calculated in both directions for patients positioned with one and three skin marks. Frequency of deviations was also examined for both groups. Results: The population mean, systematic and random errors for Group 1 and 2 for the L–R direction were 0·0, 4·4, 4·8 and 0·4, 3·1 and 3·3 mm, respectively, and in the S–I direction: 0·1, 3·4, 4·2 and 1·2, 2·7 and 3·3 mm, respectively. Frequency of images within the clinical tolerance of 5 mm was 47·1% for Group 1 and 65·9% for Group 2. Conclusion: Three skin marks are recommended for patients receiving a fractionated course of palliative RT, as it reduces set-up error, reduces the number of gross displacements (>10 mm) and increases the number of displacements within the clinically acceptable tolerance of 5 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.