The QFR computation improved the diagnostic accuracy of 3-dimensional quantitative coronary angiography-based identification of stenosis significance. The favorable results of cQFR that does not require pharmacologic hyperemia induction bears the potential of a wider adoption of FFR-based lesion assessment through a reduction in procedure time, risk, and costs.
BackgroundQuantitative flow ratio (QFR) is a novel modality for physiological lesion assessment based on 3‐dimensional vessel reconstructions and contrast flow velocity estimates. We evaluated the value of online QFR during routine invasive coronary angiography for procedural feasibility, diagnostic performance, and agreement with pressure‐wire–derived fractional flow reserve (FFR) as a gold standard in an international multicenter study.Methods and Results
FAVOR II E‐J (Functional Assessment by Various Flow Reconstructions II Europe‐Japan) was a prospective, observational, investigator‐initiated study. Patients with stable angina pectoris were enrolled in 11 international centers. FFR and online QFR computation were performed in all eligible lesions. An independent core lab performed 2‐dimensional quantitative coronary angiography (2D‐QCA) analysis of all lesions assessed with QFR and FFR. The primary comparison was sensitivity and specificity of QFR compared with 2D‐QCA using FFR as a reference standard. A total of 329 patients were enrolled. Paired assessment of FFR, QFR, and 2D‐QCA was available for 317 lesions. Mean FFR, QFR, and percent diameter stenosis were 0.83±0.09, 0.82±10, and 45±10%, respectively. FFR was ≤0.80 in 104 (33%) lesions. Sensitivity and specificity by QFR was significantly higher than by 2D‐QCA (sensitivity, 86.5% (78.4–92.4) versus 44.2% (34.5–54.3); P<0.001; specificity, 86.9% (81.6–91.1) versus 76.5% (70.3–82.0); P=0.002). Area under the receiver curve was significantly higher for QFR compared with 2D‐QCA (area under the receiver curve, 0.92 [0.89–0.96] versus 0.64 [0.57–0.70]; P<0.001). Median time to QFR was significantly lower than median time to FFR (time to QFR, 5.0 minutes [interquartile range, –6.1] versus time to FFR, 7.0 minutes [interquartile range, 5.0–10.0]; P<0.001).ConclusionsOnline computation of QFR in the catheterization laboratory is clinically feasible and is superior to angiographic assessment for evaluation of intermediary coronary artery stenosis using FFR as a reference standard.Clinical Trial Registration
URL: https://www.clinicaltrials.gov. Unique identifier: NCT02959814.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.