Background
The allocation system for heart donors in the United States changed on October 18, 2018. The typical distance from donor hospitals to recipient hospitals has increased as has the ischemic time. We investigated patient outcomes with the new allocation system and the differential effects of ischemic time under both the old and new allocation schemas.
Methods
The United Network for Organ Sharing Registry (UNOS) was queried for data regarding heart transplants occurring from October 1, 1987 to March 1, 2021. In total, 62,301 adult heart transplants were examined. Survival outcomes at 30 days and 1 year and ischemic times were compared via adjusted logistic and Cox models (overall survival and time until post‐transplant rejection).
Results
Mean ischemic time was slightly increased in the new system (3.43 h vs. 3.03 h, p < .001). Survival differences between old versus new systems were not observed in adjusted models (p = .818). However, there was evidence to suggest longer ischemic times are more detrimental to long‐term survival under the new system (hazard ratio [HR] = 1.15 per hour increase; p = .001) versus the old system (HR = 1.08 per hour increase; p < .001), although this relationship did not reach statistical significance (p = .150).
Conclusions
Although travel distances have significantly increased under the new allocation system, survival outcomes remain largely unchanged. Ischemic time is an influential factor in recipient survival that should be limited during organ transport. Further studies on the impact of travel distances and ischemic time under the new allocation system are needed.
Background
While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure-of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM).
Methods
We reviewed records of patients (N = 629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques.
Results
A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (p = 0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (p = 0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (p = 0.044).
Conclusions
The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.