BackgroundElectromagnetic guidance reveals needle alignment and position relative to the image plane on an ultrasound view. This study compared the early learning curves of novices performing ultrasound-guided needle placement with (n = 10) or without electromagnetic guidance (n = 10).MethodsParticipants performed 30 ultrasound-guided needle placements using an echogenic stick (0.3-cm diameter) as a target inside a phantom model; this early learning period was divided into sequential periods (P1: 1–5, P2: 6–10, P3: 11–15, P4: 16–20, P5: 21–25, P6: 26–30 attempts).ResultsUsing an in-plane approach, the time required for needle placement in the EMG group was significantly shorter than that of the non-EMG group in P1, P2, P4, and P6 and the number of needle advances of the EMG group was significantly smaller than that of the non-EMG group in P1 and P2. Using an out-of-plane approaches, the time required for needle placement in the EMG group was significantly shorter than that of the non-EMG group in all periods, but the number of needle advances was similar between both groups in P1–P5.ConclusionsThe electromagnetic guidance system may be beneficial when performing ultrasound guided peripheral nerve blocks or vascular cannulation in the early learning period, especially by inexperienced operators with reducing patient risk.
Background:There is a risk of drug sorption into an intravenous administration set composed of polyvinyl chloride (PVC), polyurethane (PU), or polyolefin (PO). This has implications on the dose of the active ingredient the patient receives, and thus therapeutic success. This study aimed to determine the plasma concentration of nitroglycerin and the effect of nitroglycerin on patients based on the composition of the administration set.Methods:Using a randomized, open-labeled, 3 × 3 crossover method, 9 volunteers were assigned to 3 groups. In period I, nitroglycerin (100 μg/mL) was infused via a PVC- (group A), PU- (group B), or PO-based (group C) administration set. In period II, PU- (group A), PO- (group B), and PVC-based (group C) administration sets were used, and in period III, PO- (group A), PVC- (group B), and PU-based (group C) administration sets were used. The rate of drug administration in all periods was 12 mL/hour for 30 minutes using an infusion pump. Blood samples were collected, and the plasma concentrations of nitroglycerin were analyzed using validated high-performance liquid chromatography coupled with tandem mass spectrometry. Blood pressure was determined using a sphygmomanometer applied to the other upper arm at an interval of 5 minutes.Results:We observed that the mean plasma concentration of nitroglycerin over time when administered using a PO-based tube was higher than that when using a PU- or PVC-based tube. When the percent change of the mean arterial pressure from baseline at each time point was compared among groups, there were statistically significant differences between PU and PO or PVC at most points during nitroglycerin infusion.Conclusion:Our results showed higher nitroglycerin plasma concentration and lower arterial pressure when a PO-based administration set was used than when a PVC- or PU-based administration set was used. PO-based administration sets may be more appropriate for nitroglycerin administration compared to those composed of PVC or PU.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.