Computed tomography (CT) has great clinical utility and its usage has increased dramatically over the years. Concerns have been raised, however, about health impacts of ionising radiation exposure from CTs, particularly in children, who have a higher risk for some radiation induced diseases. Direct estimation of the health impact of these exposures is needed, but the conduct of epidemiological studies of paediatric CT populations poses a number of challenges which, if not addressed, could invalidate the results. The aim of the present paper is to review the main challenges of a study on the health impact of paediatric CTs and how the protocol of the European collaborative study EPI-CT, coordinated by the International Agency for Research on Cancer (IARC), is designed to address them. The study, based on a common protocol, is being conducted in Belgium, Denmark, France, Germany, the Netherlands, Norway, Spain, Sweden and the United Kingdom and it has recruited over one million patients suitable for long-term prospective follow-up. Cohort accrual relies on records of participating hospital radiology departments. Basic demographic information and technical data on the CT procedure needed to estimate organ doses are being abstracted and passive follow-up is being conducted by linkage to population-based cancer and mortality registries. The main issues which may affect the validity of study results include missing doses from other radiological procedures, missing CTs, confounding by CT indication and socioeconomic status and dose reconstruction. Sub-studies are underway to evaluate their potential impact. By focusing on the issues which challenge the validity of risk estimates from CT exposures, EPI-CT will be able to address limitations of previous CT studies, thus providing reliable estimates of risk of solid tumours and leukaemia from paediatric CT exposures and scientific bases for the optimisation of paediatric CT protocols and patient protection.
Medical diagnostic examinations, although delivering low doses of ionizing radiation, are the main man-made source of ionizing radiation exposure for the general population. The number of procedures performed has grown dramatically in high-income countries in recent decades. 1 Among
Implementation of in vivo high-resolution micro-computed tomography (µCT), a powerful tool for longitudinal analysis of murine lung disease models, is hampered by the lack of data on cumulative low-dose radiation effects on the investigated disease models. We aimed to measure radiation doses and effects of repeated µCT scans, to establish cumulative radiation levels and scan protocols without relevant toxicity. Lung metastasis, inflammation and fibrosis models and healthy mice were weekly scanned over one-month with µCT using high-resolution respiratory-gated 4D and expiration-weighted 3D protocols, comparing 5-times weekly scanned animals with controls. Radiation dose was measured by ionization chamber, optical fiberradioluminescence probe and thermoluminescent detectors in a mouse phantom. Dose effects were evaluated by in vivo µCT and bioluminescence imaging read-outs, gold standard endpoint evaluation and blood cell counts. Weekly exposure to 4D µCT, dose of 540–699 mGy/scan, did not alter lung metastatic load nor affected healthy mice. We found a disease-independent decrease in circulating blood platelets and lymphocytes after repeated 4D µCT. This effect was eliminated by optimizing a 3D protocol, reducing dose to 180–233 mGy/scan while maintaining equally high-quality images. We established µCT safety limits and protocols for weekly repeated whole-body acquisitions with proven safety for the overall health status, lung, disease process and host responses under investigation, including the radiosensitive blood cell compartment.
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.