The Fungitell assay (Associates of Cape Cod, Inc.) is a commercial test that detects (1-3)--D-glucan (BG) and is intended for diagnosis of invasive fungal infections. To evaluate the Fungitell assay, we tested serum and plasma samples from healthy blood donors and from patients with blood cultures positive for yeast or bacteria. All 36 blood donors were BG negative, and 13 of 15 candidemic patients were BG positive. Of 25 bacteremic patients, 14 (10 with gram-positive bacteremia) were BG positive. One of the latter patients with Staphylococcus aureus bacteremia also had invasive candidiasis, based on histological findings in a tissue biopsy; therefore, the BG result was a true positive. The sensitivity, specificity, and positive and negative predictive values of the Fungitell assay, by patient, for these three groups were 93.3%, 77.2%, 51.9%, and 97.8%, respectively. We also performed the Fungitell assay on sera that had been tested for Aspergillus galactomannan or Histoplasma antigen. All six Histoplasma antigen-positive patients and 31 of 32 Aspergillus galactomannan-positive patients were also BG positive. BG results for the 10 Histoplasma antigen-negative and the 32 Aspergillus galactomannan-negative patients varied, but we were unable to confirm many of the results. Between-run coefficients of variance (CVs) for the assay ranged from 3.2% to 16.8%; within-run CVs were <4.8%. The correlation coefficient for an interlaboratory reproducibility study was 0.9892. Concentrations of hemoglobulin, bilirubin, and triglycerides that caused 20% interference were 588, 72, and 466 mg/dl, respectively. Our results suggest that the Fungitel assay may be most useful for excluding invasive fungal infection.
We developed a multiplexed indirect immunofluorescent assay for antibodies to pneumococcal polysaccharides (PnPs) based on the Luminex multiple analyte profiling system (Luminex, Austin, TX). The assay simultaneously determines serum IgG concentrations to 14 PnPs serotypes: 1, 3, 4, 5, 6B, 7F, 8, 9N, 9V, 12F; 14, 18C, 19F, and 23F. To assess the specificity of the multiplexed assay for each individual serotype, inhibition-of-binding studies were conducted using adult serum samples obtained after pneumococcal vaccination. Except for the closely related serotypes 9V and 9N, we demonstrated inhibition by homologous serotypes of more than 95% and inhibition by heterologous serotypes of less than 15% for all 14 PnPs serotypes. There was, however, high heterologous inhibition of 50% or greater with some serotypes. These cross-reacting antibodies could not be removed by preabsorption with pneumococcal C-polysaccharide but were removed by additional preabsorption with serotype 22F polysaccharide. The multiplexed Luminex assay showed good overall agreement with a well-established enzyme-linked immunosorbent assay that is currently recommended for evaluation of pneumococcal vaccine immunogenicity.
We used a multiplexedfluorescent microsphere immunoassay to develop a sandwich capture assay to assess simultaneously the production of thymus helper (TH) 1- and TH2-type cytokines in tissue culture supernatant obtained from stimulated peripheral blood mononuclear cells. The assay then was used to assess the cytokine production of patients with hyperimmunoglobulinemia E syndrome and in cord blood from neonates. The multiplexed assay has a reportable range of less than 10 to 50,000 pg/mL. For linearity and recovery studies, R2 values for the 6 cytokines ranged from 0.988 to 0.999 for samples spiked with known concentrations of recombinant cytokine standards and for patient samples. The assay showed good specificity, with little cross-reactivity between cytokines. Results from supernatants of Staphylococcus aureus-stimulated peripheral blood mononuclear cells obtainedfrom 6 patients with hyperimmunoglobulinemia E syndrome showed significantly less interferon (IFN)-gamma production than cells from healthy control subjects. Cord blood cells from neonates produced significantly less interleukin 12 and IFN-gamma than cells from adults in group B streptococci-stimulated mononuclear cells. The fluorescent multiplexed microsphere immunoassay can be used to quantitate multiple cytokines from 1 sample and should be useful for further understanding of the cytokine role in disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.