Interventional procedures are increasing in developing countries, not only for adults but also for pediatric patients. The situation with respect to staff protection is considered generally acceptable, but this is not the case for patient protection. Many patients exceeded the dose threshold for erythema. A substantial number (62%) of percutaneous transluminal coronary angioplasty procedures performed in developing countries in this study are above the currently known dose reference level and thus could be optimized. Therefore, this study has significance in introducing the concept of patient dose estimation and dose management.
The aims of this study were to investigate the frequency of computed tomography (CT) examinations for paediatric patients below 15 y of age in 128 CT facilities in 28 developing countries of Africa, Asia and Eastern Europe and to assess the magnitude of CT doses. Radiation dose data were available from 101 CT facilities in 19 countries. The dose assessment was performed in terms of weighted CT dose index (CTDI(w)), volume CT index and dose length product (DLP) for chest, chest (high resolution), lumbar spine, abdomen and pelvis CT examinations using standard methods. The results show that on average the frequency of paediatric CT examinations was 20, 16 and 5 % of all CT examinations in participating centres in Africa, Asia and Eastern Europe, respectively. Eleven CT facilities in six countries were found to use adult CT exposure parameters for paediatric patients, thus indicating limited awareness and the need for optimisation. CT images were of adequate quality for diagnosis. The CTDI(w) variations ranged up to a factor of 55 (Africa), 16.3 (Asia) and 6.6 (Eastern Europe). The corresponding DLP variations ranged by a factor of 10, 20 and 8, respectively. Generally, the CTDI(w) and DLP values in Japan are lower than the corresponding values in the three regions in this study. The study has indicated a stronger need in many developing countries to justify CT examinations in children and their optimisation. Awareness, training and monitoring of radiation doses is needed as a way forwards.
The purpose of this study was to estimate the computed tomography (CT) examination frequency, patient radiation exposure, effective doses and national diagnostic reference levels (NDRLs) associated with CT examinations in clinical practice. A structured questionnaire-type form was developed for recording examination frequency, scanning protocols and patient radiation exposure during CT procedures in fully equipped medical facilities across the country. The national annual number of CT examinations per 1000 people was estimated to be 3 procedures. The volume-weighted CT dose index, dose length product, effective dose and NDRLs were determined for 20 types of adult and paediatric CT examinations. Additionally, the CT annual collective effective dose and effective dose per capita were approximated. The radiation exposure during CT examinations was broadly distributed between the facilities that took part in the study. This calls for a need to develop and implement diagnostic reference levels as a standardisation and optimisation tool for the radiological protection of patients at all the CT facilities nationwide.
The purpose of this prospective study at 73 facilities in 18 countries in Africa, Asia and Eastern Europe was to investigate if the CT doses to adult patients in developing countries are higher than international standards. The dose assessment was performed in terms of weighted computed tomography dose index (CTDIw) and dose length product (DLP) for chest, chest (high resolution), lumbar spine, abdomen and pelvis CT examinations using standard methods. Except in one case, the mean CTDIw values were below diagnostic reference level (DRL) while for DLP, 17 % of situations were above DRLs. The resulting CT images were of adequate quality for diagnosis. The CTDIw and DLP data presented herein are largely similar to those from two recent national surveys. The study has shown a stronger need to create awareness and training of radiology personnel as well as monitoring of radiation doses in many developing countries so as to conform to the ALARA principle.
The aim of this study was to estimate radiation doses patients and staff are exposed to during interventional procedures (IPs), compare them with the international diagnostic reference levels and to develop initial National Diagnostic Reference Levels. The IP survey was undertaken as the initial task of which, retrospective data were collected from the only four Kenyan hospitals carrying out interventional radiology and cardiology procedures at the time of the study. Real-time measurement of radiation dose to patients and staff during these procedures was done. To the patients, kerma-area product (KAP) and fluoroscopy time measurements were done using an in-built KAP meter, while peak skin dose (PSD) was measured using slow Extended Dose Range (EDR2(®)) radiographic films. The staff occupational doses were measured using individual thermoluminescence dosemeters. The maximum and minimum KAP values were found to be 137.1 and 4.2 Gy cm(2), while the measured PSD values were 740 and 52 mGy, respectively. The fluoroscopic time range was between 3.3 and 70 min. The staff doses per procedure ranged between 0.05 and 1.41 mSv for medical doctors, 0.03 and 1.16 mSv for nurses, 0.04 and 0.78 mSv for radiographers and 0.04 and 0.88 mSv for clinical staff. The measured patient PSDs were within the threshold limit for skin injuries. However, with the current few IP specialists, an annual increase in workload as determined in the study will result in the International Commission on Radiation Protection annual eye lens dose limit being exceeded by 10 %. A concerted effort is required to contain these dose levels through use of protective gear, optimisation of practice and justification.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.