Background
In 2006 and 2007 we performed double lung transplantation with marginal donor lungs assessed and reconditioned by Ex Vivo Lung Perfusion (EVLP), using a technique developed by Professor Stig Steen. Here we present a 10-year follow-up comparing the outcomes of lung transplantations performed at our clinic using EVLP lungs vs. conventional lungs.
Method
Between 2006 and 2007, 21 patients (6 EVLP, 15 conventional) underwent double lung transplantation (LTx) with follow-up on May 2017 at Lund University Hospital, Sweden. Pulmonary function was measured at 3/6/12 months, and annually thereafter for a period of 10 years in addition to survival and freedom from chronic lung allograft dysfunction (CLAD) being analyzed.
Results
Regarding Forced Expiratory Volume in 1 s (FEV1) and 6MWT at 3, 6, and 12 months and annually thereafter, no difference in median FEV1 nor 6MWT was found for EVLP-LTx vs. conventional-LTx (
p
> 0.05). No difference was shown in post-operative survival between EVLP-LTx vs. conventional LTx for patients with an overall survival up to 10-years (p > 0.05). The same pattern was shown in sub analyses for patients with a limited survival up to 1 and 5 years (p > 0.05).
Conclusion
No superiority was found in conventional-LTx over EVLP-LTx, neither in long-term survival nor pulmonary function. No difference in CLAD-free survival was seen between the two groups. We believe that EVLP is a safe and effective method to use in LTx, greatly increasing the donor pool by improving marginal lungs and providing an objective assessment of the viability of marginal donor lungs.
IntroductionIn this cohort study, we evaluated whether the particles in exhaled air (PExA) device can be used in conjunction with mechanical ventilation during surgery. The PExA device consists of an optical particle counter and an impactor that collects particles in exhaled air. Our aim was to establish the feasibility of the PExA device in combination with mechanical ventilation (MV) during surgery and if collected particles could be analysed. Patients with and without nonsmall cell lung cancer (NSCLC) undergoing lung surgery were compared to normal breathing (NB) patients with NSCLC.MethodsA total of 32 patients were included, 17 patients with NSCLC (MV-NSCLC), nine patients without NSCLC (MV-C) and six patients with NSCLC and not intubated (NB). The PEx samples were analysed for the most common phospholipids in surfactant using liquid-chromatography-mass-spectrometry (LCMS).ResultsMV-NSCLC and MV-C had significantly lower numbers of particles exhaled per minute (particle flow rate; PFR) compared to NB. MV-NSCLC and MV-C also had a siginificantly lower amount of phospholipids in PEx when compared to NB. MV-NSCLC had a significantly lower amount of surfactant A compared to NB.ConclusionWe have established the feasibility of the PExA device. Particles could be collected and analysed. We observed lower PFR from MV compared to NB. High PFR during MV may be due to more frequent opening and closing of the airways, known to be harmful to the lung. Online use of the PExA device might be used to monitor and personalise settings for mechanical ventilation to lower the risk of lung damage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.