No abstract
The quality of pediatric resuscitative care delivered across the spectrum of emergency departments (EDs) in the United States is poorly described. In a recent study, more than 4000 EDs completed the Pediatric Readiness Survey (PRS); however, the correlation of PRS scores with the quality of simulated or real patient care has not been described. OBJECTIVE To measure and compare the quality of resuscitative care delivered to simulated pediatric patients across a spectrum of EDs and to examine the correlation of PRS scores with quality measures. DESIGN, SETTING, AND PARTICIPANTS This prospective multicenter cohort study evaluated 58 interprofessional teams in their native pediatric or general ED resuscitation bays caring for a series of 3 simulated critically ill patients (sepsis, seizure, and cardiac arrest). MAIN OUTCOMES AND MEASURES A composite quality score (CQS) was measured as the sum of 4 domains: (1) adherence to sepsis guidelines, (2) adherence to cardiac arrest guidelines, (3) performance on seizure resuscitation, and (4) teamwork. Pediatric Readiness Survey scores and health care professional demographics were collected as independent data. Correlations were explored between CQS and individual domain scores with PRS. RESULTS Overall, 58 teams from 30 hospitals participated (8 pediatric EDs [PEDs], 22 general EDs [GEDs]). The mean CQS was 71 (95% CI, 68-75); PEDs had a higher mean CQS (82; 95% CI, 79-85) vs GEDs (66; 95% CI, 63-69) and outperformed GEDs in all domains. However, when using generalized estimating equations to estimate CQS controlling for clustering of the data, PED status did not explain a higher CQS (β = 4.28; 95% CI, −4.58 to 13.13) while the log of pediatric patient volume did explain a higher CQS (β = 9.57; 95% CI, 2.64-16.49). The correlation of CQS to PRS was moderate (r = 0.51; P < .001). The correlation was weak for cardiac arrest (r = 0.24; P = .07), weak for sepsis (ρ = 0.45; P < .001) and seizure (ρ = 0.43; P = .001), and strong for teamwork (ρ = 0.71; P < .001). CONCLUSIONS AND RELEVANCE This multicenter study noted significant differences in the quality of simulated pediatric resuscitative care across a spectrum of EDs. The CQS was higher in PEDs compared with GEDs. However, when controlling for pediatric patient volume and other variables in a multivariable model, PED status does not explain a higher CQS while pediatric patient volume does. The correlation of the PRS was moderate for simulation-based measures of quality.
Objectives: The Emergency Severity Index (ESI) triage algorithm is a five-level triage acuity tool used by emergency department (ED) triage nurses to rate patients from Level 1 (most acute) to Level 5 (least acute). ESI has established reliability and validity in an all-age population, but has not been well studied for pediatric triage. This study assessed the reliability and validity of the ESI for pediatric triage at five sites.Methods: Interrater reliability was measured with weighted kappa for 40 written pediatric case scenarios and 100 actual patient triages at each of five research sites (independently rated by both a triage nurse and a research nurse). Validity was evaluated with a sample of 200 patients per site. The ESI ratings were compared with outcomes, including hospital admission, resource consumption, and ED length of stay.Results: Interrater reliability was 0.77 (95% confidence interval [CI] = 0.76 to 0.78) for the scenarios (n = 155 nurses) and 0.57 (95% CI = 0.52 to 0.62) for actual patients (n = 498 patients). Inconsistencies in triage were noted for the most acute and least acute patients, as well as those less than 1 year of age and those with medical (rather than trauma) chief complaints. For the validity cohort (n = 1,173 patients), outcomes differed by ESI level, including hospital admission, which went from 83% for Level 1 patients to 0% for Level 5 (chi-square, p < 0.0001). Nurses from dedicated pediatric EDs were 31% less likely to undertriage patients than nurses in general EDs (odds ratio [OR] = 0.31, 95% CI = 0.14 to 0.67).Conclusions: Reliability of the ESI for pediatric triage is moderate. The ESI provides a valid stratification of pediatric patients into five distinct groups. We found several areas in which nurses have difficulty triaging pediatric patients consistently. The study results are being used to develop pediatric-specific ESI educational materials to strengthen reliability and validity for pediatric triage.ACADEMIC EMERGENCY MEDICINE 2009; 16:843-849 ª
This review highlights the lack of robust studies and heterogeneity of literature comparing practice patterns of PEM-trained physicians with GEDPs. We have outlined a systematic approach to reviewing a body of literature for topics that lack clear terms of comparison across studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.