This study is a consequence of a distinct fish decline in the Danube river since the beginning of the 1990s. In contrast to the decline of fish population, former studies have repeatedly documented that the water quality along the Danube river is improving. However, the conclusion of a pilot study in 2002 was that a high hazard potential is associated with local sediments. The present study documents that sediment samples from the Danube river showed comparatively high aryl hydrocarbon receptor mediated activity in biotests, using the cell lines GPC.2D.Luc, H4IIE (DR-CALUX) and RTL-W1. The combination of chemical analysis, fractionation techniques and different in vitro tests revealed that priority pollutants could not explain the main induction, even though the concentrations of priority polycyclic aromatic hydrocarbons (PAHs) were very high (maximum in the tributary Schwarzach, sum of 16 EPA PAHs 26 mug/g). In conclusion, this investigation shows that nonpriority pollutants mainly mediate the high induction rates. Nevertheless, owing to the effects of PAHs towards fish and the connection between dioxin-like activity and carcinogenicity, the link between contamination and the fish population decline cannot be ruled out.
The use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described. The potential of using atmospheric-pressure chemical ionization (APCI) coupled to a tandem quadrupole analyzer has been validated for the identification and quantification of dioxins and furans in different complex matrices. The main advantage of using the APCI source is the soft ionization at atmospheric pressure, which results in very limited fragmentation. APCI mass spectra are dominated by the molecular ion cluster, in contrast with the high energy ionization process under electron ionization (EI). The use of the molecular ion as the precursor ion in MS/MS enhances selectivity and, consequently, sensitivity by increasing the signal-to-noise ratios (S/N). For standard solutions of 2,3,7,8-TCDD, injections of 10 fg in the splitless mode on 30-or 60-m-length, 0.25 mm inner diameter (id), and 25 μm film thickness low-polarity capillary columns (DB5MS type), signal-to-noise (S/N) ratios of >10:1 were routinely obtained. Linearity was achieved in the region (correlation coefficient of r 2 > 0.998) for calibration curves ranging from 100 fg/μL to 1000 pg/μL. The results from a wide variety of complex samples, including certified and standard reference materials and samples from several QA/QC studies, which were previously analyzed by EI HRGC/HRMS, were compared with the results from the APGC/MS/MS system. Results between instruments showed good agreement both in individual congeners and toxic equivalence factors (TEQs). The data show that the use of APGC in combination with MS/MS for the analysis of dioxins has the same potential, in terms of sensitivity and selectivity, as the traditional HRMS instrumentation used for this analysis. However, the APCI/MS/MS system, as a benchtop system, is much easier to use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.