Background and Aims Primary aldosteronism is a rare cause of high blood pressure (BP). Guidelines recommend a screening in several situations, such as hypertension with hypokalemia, sleeping apnea or adrenal mass, by determining the baseline aldosterone/renin ratio. Recent studies point out that hyperaldosteronism may be more frequent than expected in patients who do not have an arbitrary high aldosterone/renin ratio. The application of big data techniques could generate “red flags” that help clinicians to anticipate the diagnosis. We have evaluated the usefulness of big data in the diagnosis of hyperaldosteronism. Method We have used 3 data sources: patient management, laboratory data management and clinical record. With them, Oracle database management system extracts demographic data, blood pressure and analytical values in a single collection. This data are stored in a MongoDB database, where two collections are generated: "patients" (data we are collecting) and "variables" (values obtained from the identifiers of the latest data obtained from the source systems are saved to guide the collection process). Since MongoDB is a schemaless system, it is possible to easily add new variables and their results to the collection "patients", if it is necessary, in order to generate alerts. In order to diagnose hyperaldosteronism, age between 18 and 55 years, BP > 139/89 mmHg, K 3.5 mEq/l and plasma bicarbonate > 26 mEq/L were used. Results From January 2019 to 30th March 2020, 952,520 data were collected and 281,661 outcome variables from 80,410 patients were analyzed. The method generated alerts of possible hyperaldosteronism in 33 patients (18 men, mean age 46.8 + 6.8 years old). The retrospective study of the clinical record of these patients showed that 11 (33%) had sustained hypertension and 54.5% of them needed 3 antihypertensive drugs. 2 patients suffered a severe cardiovascular event (intracranial hemorrhage). Of these 33 patients, aldosterone/renin screening was performed in 2, 2 other patients had an abdominal CT scan, in which no adrenal masses were found. No specific studies were performed to definitively rule out hyperaldosteronism in any patient. In this period of application of big data, the hospital archive coded 3 hyperaldosteronisms: 1 of them was due to Bartter syndrome, another was a misdiagnosis (androgenic syndrome) and the third one was due to medical background of hyperaldosteronism which had been operated years ago. These results were followed by a prospective screening carried on from 30th March 2020 to 1th January 2021. 776,878 supplementary data were extracted, and 232,425 variables from 13,958 patients were analyzed. The system have generated an alert for 12 patients: 2 of them have been diagnosed of primary hyperaldosteronism, another one have an adrenal mass, which is in surgical waiting list, and 3 patients (total: 50%) are waiting medical tests due to a high suspicion of hyperaldosteronism. Conclusion Big data techniques allow us to create “red flags” for the screening of rare diseases and might be an important tool in their diagnosis. Its systematic application guides us to perform specific diagnostic tests in at least 50% of the cases, in order to improve the diagnostic accuracy in these selected patients.
Background and Aims Current guidelines emphasize the need for surveillance of vascular access (VA) for hemodialysis (HD), especially arteriovenous fistulas (AVF). Detecting a reduction in VA flow is auseful tool to anticipate the complications of VA as thrombosis. The DMed NephroFlow(NIPRO®) system, based on ultrasound dilution (UD) methods, has been shown tobe comparable to the classic Transonic® measurement system for estimating VA flow and canbe applied for VA surveillance. Our objetctive is to determine if there are significant differences when performing flow measurements with NephroFlow® between the first hour and the second hour of the HD session, as well as between any of the three days in which the patient attends HD. Method For two consecutive weeks, patients with AVF or graft (gAVF) on HD in our unit underwent VA flow measurements using the NephroFlow® system at the first and second hour of HD, on the 3 days that they attended HD sessions. Interspersing the first hour with the second each week to avoid significant loss in HD quality. For the study, we proceeded according to the usual recommendations of stable flow at 250 ml/min, corresponding ultrafiltration rate, needles in the same vein, without change in dry weight, with the same nurse staff, and transferring all patients to conventional HD. Results Twenty-one patients have been included, 13 male and 8 female, mean age 68±12.3 years. The mean time on HD was 36±23 months. The type of VA was: 10 patients presented a radiocephalic AVF, 5 brachiocephalic AVF, 2 patients a brachiobasilic AVF, and 4 patients a gAVF. The estimated mean flow obtained by NephroFlow ® in the first hour of all sessions and in the second hour was 1056 ± 754 and 1130.16 ± 769 ml/min, respectively; intraclass correlation index was 0.737 and K-W Test H 0.349 (p≤0.05). The mean flow on the first day was 1129±794.5ml/min, ICC = 0.662; second day 1027.5±729ml/min, ICC = 0.812; third day 1121.5±±ml/min, ICC = 0.774. In all cases p<0.05. Conclusion No significant differences have been observed in the VA flow estimated with the NephroFlow® ultrasound dilution system, neither at measurement time (the first or the second hour of HD session) nor day of performance (first, second or third day of HD session of the week). NephroFlow® UD system may be a useful tool for VA surveillance and could be applied when is necessary.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.