Spray sprinklers enable to operate at low pressures (<103 kPa) in self-propelled irrigation machines. A number of experiments were performed to characterize the water distribution pattern of an isolated rotator spray plate sprinkler operating at very low pressure under different experimental conditions. The experiments were performed under two pressures (69 kPa and 103 kPa) and in calm and windy conditions. The energy losses due to the impact of the out-going jet with the sprinkler plate were measured using an optical technique. The adequacy to reproduce the measured water distribution pattern under calm conditions of two drop size distribution models was evaluated. A ballistic model was used to simulate the water distribution pattern under wind conditions evaluating three different drag models: (1) considering solid spherical drops; (2) a conventional model based on wind velocity and direction distortion pattern, and (3) a new drag coefficient model independent of wind speed. The energy losses measured with the optical method range from 20% to 60% from higher to lower nozzle sizes, respectively, for both evaluated working pressures analyzing over 16,500 droplets. For the drop size distribution selected, Weibull accurately reproduced the water application with a maximum root mean square error (RMSE) of 19%. Up to 28% of the RMSE could be decreased using the wind-independent drag coefficient model with respect to the conventional model; the difference with respect to the spherical model was 4%.
Numerous methodologies have been developed to characterize sprinkler irrigation drops with the purpose of improving irrigation efficiency and controlling soil erosion and compaction. This paper presents the laboratory characterization of the morphology and velocity of drops in their free-falling trajectory as influenced by drop diameter and wind speed. For this purpose, a Particle Tracking Velocimetry technique with in-line volumetric illumination was implemented. Hypodermic needles were used to produce droplets of uniform size. Two needle diameters resulted in drops with average diameters of 1.94 and 2.94 mm. Drops were illuminated with a double-pulsed laser beam or a LED lamp. Drop characterization reached an elevation of 4.28 m and occasionally attained terminal velocity. Motion blur was suppressed using a deconvolution filter. Drop equivalent diameter, velocity, chord ratio, canting angle and trajectory angle were determined using an ad-hoc software. The experimental approach led to the measurement of real drop size by illuminating a volume in the capture zone; Drop shape ranged from quasi-sphere to
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.