ARTICLE INFO ABSTRACT Article history:This paper describes a fabrication multiplexing sensor probe that employs a fiber Bragg grating(FBG) based on multiple measurements to determine the blade deflection of a wind power generator the reliability analysis of this probe is also presented. To diminish the temperature sensitivity of the FBG sensor, we form multiple CFRPs onto the upper and lower layers of the FBG and package it with an epoxy resin. As a result, the depth of the CFRP is 1mm, and the temperature sensitivity is 2.39pm/℃. We construct a sensor network utilizing the fabricated sensor with a blade beam model. As the number of pendulums is increased on the fore-end of the beam, the strain value is measured. The strain variation is calculated from the measurement of the load on the blade beam model by monitoring the strain of the FBG sensor. When the linear equation is applied, the strain error is 0.4% and when the finite difference method is used, the tip deflection error is 3.3%. The displacement error derived from the strain value of the FBG sensor is 4.39%. The calculated result between the measured value of the dead-end of the beam and the strain is less than 2.46% tip distortion error. Therefore, our proposed multiplexing sensor probe is a low-cost and high-reliability solution for a commercial wind power generator.
This research focuses on the development of an interrogator that operates and measures fiber Bragg grating(FBG) multiplexing sensor probes for accuratemeasurement of the blade deflection in a wind power generator. We designed and fabricated an optical source and spectrum module for the interrogator. Additionally, we verified the wavelength repeatability within 0.001 nm and the wavelength stability within 1 pm of the optical source, and we experimentally determined that the wavelength scanning range was about 44.4 nm. The FBG sensor with 2 nm resolution can be extended to a performance-efficient system that measures more than 20 sensors. The implemented interrogator has 0.141 nm wavelength variations corresponding to an ambient temperature range of 0℃ to 70℃. The measurement error can be easily reduced by employing a temperature compensation algorithm. In this study, we quantitatively confirmed the accuracy and operating stability of the interrogator.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.