Introduction Previous articles reported on the tip–apex distance, lag screw placement, fracture pattern, reduction quality, osteoporosis and other factors associated with second surgery. The current study focused on investigating the association of the matching degree between proximal femoral intramedullary nail and femoral medullary cavity on reoperation rate. Patients and methods A retrospective cohort study was conducted. It included patients with intertrochanteric fracture who were treated with proximal femoral anti-rotatory intramedullary nail (PFNA) between January 2016 and April 2021. The gap between the intramedullary nail and the femoral medullary cavity was equal to the difference in diameter between the two. According to the gap size, all patients were divided into three groups, as follows: high-matching group: gap ≤ 2 mm; middle-matching group: 2 < gap < 4 mm; and low-matching group: gap ≥ 4 mm. The mean gap was measured through standard images. The primary observational index was whether the reoperation was needed, and secondary observational indexes included operative time, length of hospital stay. Patient characteristics were recorded, as follows: age, sex, follow-up time, fracture pattern, reduction grade and length of intramedullary nail. Results A total of 203 eligible patients were recorded, including 78 males (38.4%) and 125 females (61.6%). They had a mean age of 77.8 ± 9.9 years old and an average follow-up time of 58.1 ± 24.0 weeks. Twenty-seven patients (13.3%) needed a second operation. Coxa varus combined with screw cutting was the most common reason for reoperation (11 cases). Unstable fracture pattern with poor reduction grade tended to contribute to reoperation, whose odds ratio (OR) was 6.61 (95% confidence interval [CI], 1.98–22.09; P = 0.002). The three groups had 11 cases (13.7%), 12 cases (13.8%) and 4 cases (11.1%) of reoperation, respectively, and logistic regression showed no significant association was noted between matching degree of intramedullary nail and reoperation rate. Conclusions The matching degree between proximal femoral intramedullary nail and femoral medullary cavity did not seem to be an important factor for reoperation, which offered more options of intramedullary nail size intraoperatively and reduced implants stock from inventory.
IntroductionPrevious articles reported on the tip-apex distance, lag screw placement, fracture pattern, reduction quality, osteoporosis and other factors associated with second surgery. The current study focused on investigating the association of the matching degree between proximal femoral intramedullary nail and femoral medullary cavity on reoperation rate.Patients and methodsA retrospective cohort study was conducted. It included patients with intertrochanteric fracture who were treated with proximal femoral anti-rotatory intramedullary nail (PFNA) between January 2016 and April 2021. The gap between the intramedullary nail and the femoral medullary cavity was equal to the difference in diameter between the two. According to the gap size, all patients were divided into three groups, as follows: high-matching group: gap ≤ 2 mm; middle-matching group: 2 < gap < 4 mm; and low-matching group: gap ≥ 4 mm. The mean gap was measured through standard images. The primary observational index was whether the reoperation was needed, and secondary observational indexes included operative time, length of hospital stay. Patient characteristics were recorded, as follows: age, sex, follow-up time, fracture pattern, reduction grade and length of intramedullary nail.ResultsA total of 203 eligible patients were recorded, including 78 males (38.4%) and 125 females (61.6%). They had a mean age of 77.8 ± 9.9 years old and an average follow-up time of 58.1 ± 24.0 weeks. Twenty-seven patients (13.3%) needed a second operation. Coxa varus combined with screw cutting was the most common reason for reoperation (11 cases). Unstable fracture pattern with poor reduction grade tended to contribute to reoperation, whose odds ratio (OR) was 6.61 (95% confidence interval [CI], 1.98–22.09; p = 0.002). The three groups had 11 cases (13.7%), 12 cases (13.8%) and 4 cases (11.1%) of reoperation respectively and logistic regression showed no significant association was noted between matching degree of intramedullary nail and reoperation rate.ConclusionsThe matching degree between proximal femoral intramedullary nail and femoral medullary cavity did not seem to be an important factor for reoperation, which offered more options of intramedullary nail size intraoperatively and reduced implants stock from inventory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.