Steel tube confined concrete (STCC) is widely used in the vertical members of high-rise buildings such as columns. The axial load is not directly resisted by the steel tube in STCC, but is resisted via the interfacial frictional stress between steel tube and concrete core, which is different with that of concrete filled steel tube (CFT) members and would effectively suppress the outward local buckling of steel tube at early stage. Recently, fibre-reinforced polymer (FRP) confined STCC presents a potential to enhance the ductility and durability of such vertical elements. This paper presents an experimental study on monotonic axial compressive behaviour of carbon FRP (CFRP) confined STCC (CFRP-STCC) stub column and an analytical study on the confinement mechanism of and the ultimate axial bearing capacity of the elements. A three-stage confinement mechanism involving the different contributions of the steel tube and the CFRP wrap in CFRP-STCC elements was proposed based on the test results. A prediction model of the ultimate axial bearing capacity of CFRP-STCC stub columns was developed subsequently. Results show that the presence of CFRP wrap enhances effectively the load-bearing capacity and the ductility of steel tube confined plain concrete and reinforced concrete elements, and significantly prevents the local buckling of the steel tubes in the elements. The proposed prediction model of ultimate axial bearing capacity assesses test results with a great agreement.
A self-sensing hybrid GFRP-concrete bridge superstructure, which consists of two bridge decks and each bridge deck is comprised of four GFRP box sections combined with a thin layer of concrete in the compression zone, was developed by using eight embedded FBG sensors in the top and bottom flanges of the four GFRP box sections at midspan section of one bridge deck along longitudinal direction, respectively. The proposed self-sensing hybrid bridge superstructure was tested in 4-point loading to investigate its flexural behavior and verify the operation of the embedded FBG sensors. The longitudinal strains of the hybrid bridge superstructure were recorded using the embedded FBG sensors as well as the surface-bonded electric resistance strain gauges. The experimental results indicate that the embedded FBG sensors can faithfully record the longitudinal strains of the hybrid bridge superstructure in tension at bottom flanges and in compression at top flanges of the four GFRP box sections over the entire loading range, as compared with the surface-bonded strain gauges. So, the proposed self-sensing hybrid GFRP-concrete bridge superstructure can reveal its internal strains in serviceability limit state as well as in strength limit state, and it will have wide applications for long-term monitoring in civil engineering.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.