In this paper, a novel fractional-order active disturbance rejection control with fuzzy self-tuning method (FSFOADRC) is proposed for photoelectric tracking system (PTS). Firstly, aiming at the internal uncertainty of PTS and external disturbance, a fraction-order extended state observer (FOESO) is designed, and the FOESO can transform the plant into a simple form, which greatly simplifies the mathematical model. Secondly, a fuzzy regulator is applied to the proportion–differentiation controller (PD), increasing the flexibility and adaptivity of the controller. In addition, the stability of the whole control system can be guaranteed. Eventually, numerical comparative simulations are implemented to verify the feasibility and superiority of the proposed method. Compared with the integral-order active disturbance rejection control (IOADRC), fractional-order active disturbance rejection control (FOADRC) without the fuzzy regulator and proportion–integration–differentiation (PID) controller, the proposed method performs better with faster response, smaller overshoot, and stronger disturbance suppression capability.
Permanent Magnet Synchronous Motor (PMSM) is widely used due to its advantages of high power density, high efficiency and so on. In order to ensure the reliability of a PMSM system, it is extremely vital to accurately diagnose the incipient faults. In this paper, a variety of optimization algorithms are utilized to realize the diagnosis of the faulty position and severity of the inter-turn short-circuit (ITSC) fault, which is one of the most destructive and frequent faults in PMSM. Compared with the existing research results gained by particle swarm optimization algorithms, in this paper, the methods using other optimization algorithms incorporating genetic algorithm, whale optimization algorithm and stochastic parallel gradient descent algorithm (SPGD) can acquire more stable and precise results. In particular, the method based on SPGD can obtain the most desirable performance among the methods mentioned above; that is, the relative error of short-circuit turns ratio is approximately as low as 0.03%. In addition, in the case of asymmetric input three-phase voltage and with the adverse impact of high-order harmonics at different load moments, the fault diagnosis method based on SPGD still maintains relatively satisfactory properties. Finally, the verification on the actual PMSM platform demonstrates that the SPGD can still diagnose the faulty severity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.