Background: Considerable geometrical change occurs during chemoradiotherapy (CRT) course of nasopharyngeal carcinoma (NPC). This aim of this study was to quantify the volumetric and surface variability of the target volumes (TV) and to estimate the expanded margin to maintain acceptable geometrical coverage.Methods: Twenty patients with locally advanced nasopharyngeal cancer underwent one planning CT (pCT) and six weekly repeated CT (rCT) scans during the treatment course of definitive CRT. The TV included the gross tumor volume (GTV) of the primary tumor, large (shortest diameter >3.0 cm) and small (diameter >1 cm and ≤3 cm) positive neck lymph nodes, and low-risk clinical target volume (CTV _Lr ) that were delineated manually on the pCT and each rCT. When comparing TV in pCT (V _pCT ) and TV in rCT (V _rCT ), the overlapping index (OI), Dice similarity coefficient (DSC), shortest perpendicular distance (SPD), and overall standard deviation (overall SD) were calculated to present the geometric changes. An isotropical margin was expanded outward around CTV _Lr in pCT to establish the mimic planning target volume (PTV).An OI ≥0.95 was defined as acceptable geometrical coverage.Results: For all TV, DSCs decreased, and the SPDs and overall SD increased with the increasing number of fractions delivered. The DSCs of all gross TV were <70% after the third week. The mean SPDs were 1.5-2.5 mm in the first week and 5.2-6.2 mm in the last week. The OI and DSC in concurrent CRT were smaller than those in the sequential therapy; and similarly the SPD and overall SD in the concurrent therapy were larger than those in the sequential one. To maintain >95% geometrical coverage, a 2-mm additional margin could maintain the coverage throughout the treatment course and a 1-mm margin could maintain the desired coverage if there is an adaptive re-planning no later than the third week of the treatment course.Conclusions: Both volumetric coverage and surface of the tumour underwent the progressive changes during the treatment course of CRT. One to two mm as the expanded margin to establish the PTV is required to maintain >95% geometrical coverage.
The geometrical changes of each NNL are substantial and the necessary margin of 2-5 mm depended on individual NNL is needed to maintain geometrical coverage throughout the course of IGRT for NPC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.