BackgroundSeveral 3D multi-segment foot models (MFMs) have been introduced for the in vivo analysis of dynamic foot kinematics. However, reproducibility of a model should be checked and ascertained before clinical utilization of a MFM. The purpose of this study was to determine the reliability of recently introduced MFM with a 15-marker set by assessing the participant’s stride-to-stride (intra-session) and visit-to-revisit (inter-session) repeatability.MethodsTwenty healthy adults with a mean age of 28.9 years (10 males and 10 females) were tested. Three representative strides from five separate trials were used for analysis from each session. Kinematic data of foot segmental motion was collected and tracked using the Foot3D Multi-Segment Software (Motion Analysis Co., Santa Rosa. CA). A retest was performed in the same manner at an interval of 4 weeks. Coefficients of multiple correlation (CMC) and intra-class correlation coefficient (ICC) were calculated in order to assess the intra-session and inter-session repeatability.ResultsInter-segment foot angles from healthy adults from a MFM with 15-marker set showed a narrow range of variability during the gait cycle. The mean intra-session ICC was 0.981 (±0.010), which was interpreted as excellent. The mean intra-session CMC was 0.948 (±0.027), which was interpreted as very good repeatability. The mean inter-session ICC was 0.886 (±0.047) and the mean inter-session CMC was 0.801 (±0.077), which were interpreted as excellent and good repeatability, respectively.ConclusionWe demonstrated a MFM with a 15-marker set had high intra-session and inter-session repeatability, especially in sagittal plane motion. We thought this MFM would be applicable to evaluation of the segmental foot motion during gait.
BackgroundThere have been few outcomes studies with follow-up after performing ulnar shortening osteotomy for ulnar impaction syndrome. We investigated the long-term clinical and radiological outcomes of ulnar shortening osteotomy for the treatment of idiopathic ulnar impaction syndrome.MethodsWe retrospectively reviewed 36 patients who had undergone ulnar shortening osteotomy for idiopathic ulnar impaction syndrome for a mean follow-up of 79.1 months (range, 62 to 132 months). The modified Gartland and Werley scores were measured pre- and postoperatively. The radiographic parameters for the assessment of the distal radioulnar joint (DRUJ) as well as the relationship between these radiographic parameters and the clinical and radiological outcomes were determined.ResultsThe average modified Gartland and Werley wrist score improved from 65.5 ± 8.1 preoperatively to 93.4 ± 5.8 at the last follow-up visit. The average preoperative ulnar variance of 4.7 ± 2.0 mm was reduced to an average of -0.6 ± 1.4 mm postoperatively. Osteoarthritic changes of the DRUJ were first seen at 34.8 ± 11.1 months follow-up in 6 of 36 wrists (16.7%). Those who had osteoarthritic changes in the DRUJ had significantly wider preoperative ulnar variance, a longer distal radioulnar distance and a greater length of ulnar shortening, but the wrist scores of the patients who had osteoarthritic changes in the DRUJ were comparable to those who did not have osteoarthritic changes in the DRUJ.ConclusionsThe clinical outcomes are satisfactory for even more than 5 years after ulnar shortening osteotomy for treating idiopathic ulnar impaction syndrome despite the osteoarthritic changes of the DRUJ. The patients who need a larger degree of ulnar shortening may develop DRUJ arthritis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.