BACKGROUND: Although newborn screening for critical congenital heart disease (CCHD) was recommended by the US Health and Human Services Secretary's Advisory Committee on Heritable Disorders in Newborns and Children to promote early detection, it was deemed by the Secretary of the HHS as not ready for adoption pending an implementation plan from HHS agencies. OBJECTIVE: To develop strategies for the implementation of safe, effective, and efficient screening. METHODS: A work group was convened with members selected by the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children, the American Academy of Pediatrics, the American College of Cardiology Foundation, and the American Heart Association. RESULTS: On the basis of published and unpublished data, the work group made recommendations for a standardized approach to screening and diagnostic follow-up. Key issues for future research and evaluation were identified. CONCLUSIONS: The work-group members found sufficient evidence to begin screening for low blood oxygen saturation through the use of pulse-oximetry monitoring to detect CCHD in well-infant and intermediate care nurseries. Research is needed regarding screening in special populations (eg, at high altitude) and to evaluate service infrastructure and delivery strategies (eg, telemedicine) for nurseries without on-site echocardiography. Public health agencies will have an important role in quality assurance and surveillance. Central to the effectiveness of screening will be the development of a national technical assistance center to coordinate implementation and evaluation of newborn screening for CCHD.
BACKGROUND AND OBJECTIVE New Jersey was the first state to implement legislatively mandated newborn pulse oximetry screening (POxS) in all licensed birthing facilities to detect critical congenital heart defects (CCHDs). The objective of this report was to evaluate implementation of New Jersey’s statewide POxS mandate. METHODS A 2-pronged approach was used to collect data on infants screened in all New Jersey birthing facilities from August 31, 2011, through May 31, 2012. Aggregate screening results were submitted by each birthing facility. Data on failed screens and clinical characteristics of those newborns were reported to the New Jersey Birth Defects Registry (NJBDR). Three indicators were used to distinguish the added value of mandated POxS from standard clinical care: prenatal congenital heart defect diagnosis, cardiology consultation or echocardiogram indicated or performed before PoxS, or clinical findings at the time of POxS warranting a pulse oximetry measurement. RESULTS Of 75 324 live births in licensed New Jersey birthing facilities, 73 320 were eligible for screening, of which 99% were screened. Forty-nine infants with failed POxS were reported to the NJBDR, 30 of whom had diagnostic evaluations solely attributable to the mandated screening. Three of the 30 infants had previously unsuspected CCHDs and 17 had other diagnoses or non-CCHD echocardiogram findings. CONCLUSIONS In the first 9 months after implementation, New Jersey achieved a high statewide screening rate and established surveillance mechanisms to evaluate the unique contribution of POxS. The screening mandate identified 3 infants with previously unsuspected CCHDs that otherwise might have resulted in significant morbidity and mortality and also identified other significant secondary targets such as sepsis and pneumonia.
Newborn screening for critical congenital heart defects (CCHD) was added to the US Recommended Uniform Screening Panel in 2011. Within 4 years, 46 states and the District of Columbia had adopted it into their newborn screening program, leading to CCHD screening being nearly universal in the United States. This rapid adoption occurred while there were still questions about the effectiveness of the recommended screening protocol and barriers to follow-up for infants with a positive screen. In response, the Centers for Disease Control and Prevention partnered with the American Academy of Pediatrics to convene an expert panel between January and September 2015 representing a broad array of primary care, neonatology, pediatric cardiology, nursing, midwifery, public health, and advocacy communities. The panel’s goal was to review current practices in newborn screening for CCHD and to identify opportunities for improvement. In this article, we describe the experience of CCHD screening in the United States with regard to: (1) identifying the target lesions for CCHD screening; (2) optimizing the algorithm for screening; (3) determining state-level challenges to implementation and surveillance of CCHD; (4) educating all stakeholders; (5) performing screening using the proper equipment and in a cost-effective manner; and (6) implementing screening in special settings such as the NICU, out-of-hospital settings, and areas of high altitude.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.