Heart rate variability (HRV) is a useful index of autonomic function and has been linked to the development of high altitude (HA) related illness. However, its assessment at HA has been undermined by the relative expense and limited portability of traditional HRV devices which have mandated at least a five minute heart rate recording. In this study the portable ithlete™ HRV system, which uses a 55 second recording, was compared with a reference method of HRV which utilises a five minute electrocardiograph recording (CheckMyHeart™). The root mean squares of successive R-R intervals (RMSSD) for each device was converted to a validated HRV score (lnRMSSDx20) for comparison. Twelve healthy volunteers were assessed for HRV using the two devices across seven time points at HA over 10 days. There was no significant change in the HRV values with either the ithlete (P=0.3) or the CheckMyHeart™ (p=0.19) device over the seven altitudes. There was also a strong overall correlation between the ithlete™ and CheckMyHeart™ device (r=0.86; 95% confidence interval: 0.79 to 0.91). The HRV was consistently, though nonsignificantly higher with ithlete™ than with the CheckMyHeart™ device (mean difference [bias] 1.8l; 95% CI -12.3 to 8.5). In summary the ithlete™ and CheckMyHeart™ system provide relatively similar results with good overall agreement at HA.
IntroductionSeptic acute kidney injury (AKI) is the most common complication of septic shock and increases mortality. A large body of experimental data suggests alterations in renal perfusion occur, but this is yet to be fully assessed in humans. The aim of the current study is to observe the macro and microcirculations in both the systemic and renal circulations in a cohort of patients with early septic shock.Methods and analysisSingle-centre, prospective, longitudinal, observational study of 50 patients with septic shock. Renal microcirculatory assessment will be performed with contrast-enhanced ultrasound, the sublingual microcirculation assessed with incident dark field microscopy and transthoracic echocardiography used to assess global flow. Patients will be enrolled as soon as possible after admission to the intensive care unit and then at +24,+48 and +96 hours. Blood samples of circulatory and renal biomarkers will be collected. Sample groups will be defined by the presence or absence of AKI and then subclassified by the severity (Kidney Disease Improving Global Outcomes (KDIGO) criteria), variables will be compared within and between groups over time.Ethics and disseminationResearch Ethics Committee (REC) approval has been granted for this study by Yorkshire and the Humber, Leeds West Research Ethics Committee (18/YH/0371) and due to the nature of the patients enrolled with septic shock, capacity for informed consent is likely to be lacking. Therefore, a personal consultee (friend or relative) will be consulted or a nominated consultee (clinician) in their absence. After capacity is regained, consent will then be sought from the patient in accordance with the Mental Capacity Act, UK (2005). This consent process has been approved following REC review. Results will be published in a relevant peer-reviewed journal and presented at academic meetings.
Introduction Haemorrhage is a leading cause of death following traumatic injury and the early detection of hypovolaemia is critical to effective management. However, accurate assessment of circulating blood volume is challenging when using traditional vital signs such as blood pressure. We conducted a study to compare the stroke volume (SV) recorded using two devices, trans-thoracic electrical bioimpedance (TEB) and supra-sternal Doppler (SSD), against a reference standard using trans- thoracic echocardiography (TTE). Methods A lower body negative pressure (LBNP) model was used to simulate hypovolaemia and in half of the study sessions lower limb tourniquets were applied as these are common in military practice and can potentially affect some haemodynamic monitoring systems. In order to provide a clinically relevant comparison we constructed an error grid alongside more traditional measures of agreement. Results 21 healthy volunteers aged 18–40 were enrolled and underwent 2 sessions of LBNP, with and without lower limb tourniquets. With respect to absolute SV values Bland Altman analysis showed significant bias in both non-tourniquet and tourniquet strands for TEB (-42.5 / -49.6 ml), rendering further analysis impossible. For SSD bias was minimal but percentage error was unacceptably high (35% / 48%). Degree of agreement for dynamic change in SV, assessed using 4 quadrant plots showed a seemingly acceptable concordance rate for both TEB (86% / 93%) and SSD (90% / 91%). However, when results were plotted on an error grid, constructed based on expert clinical opinion, a significant minority of measurement errors were identified that had potential to lead to moderate or severe patient harm. Conclusion Thoracic bioimpedance and suprasternal Doppler both demonstrated measurement errors that had the potential to lead to clinical harm and caution should be applied in interpreting the results in the detection of early hypovolaemia following traumatic injury.
Background: Gradual ascent to high altitude is typically associated with reduced resting aldosterone
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.