Background
Early implant placement combined with simultaneous contour augmentation was able to rebuild stable facial hard‐tissue and soft‐tissue contours that were esthetically pleasing. The purpose of this study was to evaluate the clinical esthetic outcome, when two different bone grafting materials were used.
Methods
Forty‐eight patients were randomly assigned into two groups. In the control group, autogenous bone was used to cover the exposed implant surface then a layer of deproteinized bovine bone mineral (DBBM) was added. This graft combination was then combined with a collagen membrane. In the test group, the exposed implant surface was covered with a layer of freeze‐dried bone allograft (FDBA) in combination with the collagen membrane. Modified plaque index (mPI), modified sulcular bleeding index (mSBI), probing depth (PD), keratinized mucosa (KM), implant crown length (IC), distance from the implant shoulder radiographic bone‐to‐implant contact (DIB), pink esthetic score (PES), and white esthetic score (WES) were measured at 12‐months post implant loading.
Results
All 48 implants were clinically successful, and no significant differences were observed in mPI, mSBI, PD, KM, IC, DIB, PES, and WES at 1‐year implant loading. The mean mucosal recessions of test and control group were unchanged, 0 and –0.02 mm, respectively. The mean DIB were –0.32 and –0.21 mm in test and control implants, respectively. The mean totals of PES/WES were 15.29 and 15.33 for the test and control groups, respectively, with no significant difference between groups.
Conclusion
This study demonstrated that autogenous bone plus DBBM and FDBA each combined with a collagen membrane both resulted in stable clinical and esthetic outcomes in early implant placement with contour augmentation after 1 year.
Background
Early implant placement with contour augmentation could provide support and volume to the hard and soft tissues. Herein, we aimed to ascertain whether freeze‐dried bone allograft (FDBA) shares with deproteinized bovine bone material (DBBM) the results for esthetic outcomes for anterior teeth and stability of peri‐implant facial bone thickness and height by conducting guided bone regeneration.
Methods
Forty‐eight patients were randomly assigned into two groups. In the control group, autogenous bone chips was used to cover the exposed implant surface, followed by a layer of DBBM. This graft combination was then covered with two layers of collagen membrane. In the test group, the exposed implant surface was covered with FDBA, combined with the collagen membrane. During this study, the hard tissue dimensional changes were measured at 12‐months post‐implant loading by using cone‐beam computed tomography.
Results
At 12 months postoperatively, all 48 implants were clinically successful. The mean thickness of facial bone walls ranged from 1.6 to 2.45 mm at the three levels of measurement in the control group and ranged from 1.6 to 2.10 mm in the test group. The mean facial vertical bone wall peak (IP‐FC) after loading 1 year presented with values of 0.8 mm (range, 0.0 to 1.25 mm) and 0.5 mm (range, 0.1 to 1.1 mm) coronal to the implant platform in control and test implants, respectively. There were no significant differences in facial bone wall thickness and IP‐FC between groups.
Conclusions
This study demonstrated that autogenous bone chips plus DBBM or FDBA showed similar outcome of peri‐implant buccal bone stability in early implant placement after 1 year.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.