This study investigated the performance of a single-stage scroll compressed air source heat pump coupled with a flash tank indirect vapor injection. In the refrigerant circulating piping of the heat pump, an indirect vapor injection piping connecting a flash tank at the refrigerant outlet of a condenser and the suction of a scroll compressor was designed. By the indirect refrigerant vapor injection from the flash tank, the saturation pressure and temperature of the refrigerant (R134a) in the evaporator can be raised and the sub-cooling of the refrigerant at the inlet of expansion valve can be enlarged as well. Thus, energy consumption of the compressor can be reduced and cooling capacity of the evaporator can be boosted. It was found that the suitable amount of indirect vapor refrigerant strongly depends on the operational environmental temperatures. By adjusting the suitable indirect vapor injection volume into the compressor, the performance of the heat pump was enhanced. In this study, a suitable indirect vapor injection volume was found and 5~15% performance increments can be obtained while the heat pump operated under ambient temperatures in a range from 5°C to 35°C.
In this study, we developed a new type of water-to-water two-stage screw heat pump with a vapor injection flash tank and investigated the performance of the heat pump under various condensation temperatures of the refrigeration cycle. In addition to the flash tank, a floodedtype evaporator and a shell-tube oil cooler for refrigeration oil heat recovery are implemented in the heat pump system. Suitable vapor injection pressures corresponding to different condensation temperatures were found. It was also found in this study, that with a suitable vapor injection pressure for operation, the average coefficient of heating performance can be enhanced by the investigated heat pump system under various condensation temperatures. An intelligent controlling strategy in terms of the subcooled degree was developed to attain the dynamic high performance of the heat pump under different condensation temperatures. From the performance measurements, it can be found that the average heating capacity improvement of 29% and the performance enhancement of 11% can be achieved by the two-stage water-towater heat pump by utilizing the controlling strategy to adjust the vapor injection and the oil heat recovery under different condensation temperatures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.