The microPET Focus 120 scanner is a third-generation animal PET scanner dedicated to rodent imaging. Here, we report the results of scanner performance testing. Methods: A 68 Ge point source was used to measure energy resolution, which was determined for each crystal and averaged. Spatial resolution was measured using a 22 Na point source with a nominal size of 0.25 mm at the system center and various off-center positions. Absolute sensitivity without attenuation was determined by extrapolating the data measured using an 18 F line source and multiple layers of absorbers. Scatter fraction and counting rate performance were measured using 2 different cylindric phantoms simulating rat and mouse bodies. Sensitivity, scatter fraction, and noise equivalent counting rate (NECR) experiments were repeated under 4 different conditions (energy window, 250;750 keV or 350;650 keV; coincidence window, 6 or 10 ns). A performance phantom with hot-rod inserts of various sizes was scanned, and several animal studies were also performed. Results: Energy resolution at a 511-keV photopeak was 18.3% on average. Radial, tangential, and axial resolution of images reconstructed with the Fourier rebinning (FORE) and filtered backprojection (FBP) algorithms were 1.18 (radial), 1.13 (tangential), and 1.45 mm full width at half maximum (FWHM) (axial) at center and 2.35 (radial), 1.66 (tangential), and 2.00 mm FWHM (axial) at a radial offset of 2 cm. Absolute sensitivities at transaxial and axial centers were 7.0% (250;750 keV, 10 ns), 6.7% (250;750 keV, 6 ns), 4.0% (350;650 keV, 10 ns), and 3.8% (350;650 keV, 6 ns). Scatter fractions were 15.9% (mouse phantom) and 35.0% (rat phantom) for 250;750 keV and 6 ns. Peak NECR was 869 kcps at 3,242 kBq/mL (mouse phantom) and 228 kcps at 290 kBq/mL (rat phantom) at 250;750 keV and 6 ns. Hot-rod inserts of 1.6-mm diameter were clearly identified, and animal studies illustrated the feasibility of this system for studies of whole rodents and mid-sized animal brains. Conclusion: The results of this independent field test showed the improved physical characteristics of the F120 scanner over the previous microPET series systems. This system will be useful for imaging studies on small rodents and brains of larger animals.Key Words: small-animal PET; performance measurement; instrumentation; molecular imaging; small-animal imaging PETi s a noninvasive, diagnostic imaging technique that produces functional or biochemical images of a body (1-4). Although PET is regarded as a powerful translational research tool between animal models and human clinical applications (5-8), clinical PET scanners used for human studies do not have satisfactory spatial resolution or sensitivity for studies of small animals, such as rats and mice (9-11). Because the linear dimensions of organs in these animals are 10 or more times smaller in each dimension than in human subjects, the spatial resolution of a suitable PET scanner must be similarly higher and the voxel size should also be reduced according to sampling theory (9,10). T...
Alzheimer's disease patients display neuropathological lesions, including the accumulation of amyloid-beta (Aβ) peptide and neurofibrillary tangles. Although the mechanisms causing the neurodegenerative process are largely unknown, increasing evidence highlights a critical role of immunity in the pathogenesis of Alzheimer's disease. In the present study, we investigated the role of regulatory T cells (Tregs) on Alzheimer's disease progression. First, we explored the effect of Tregs (CD4+CD25+ T cells) and Teffs (CD4+CD25− T cells) in an adoptive transfer model. Systemic transplantation of purified Tregs into 3xTg-AD mice improved cognitive function and reduced deposition of Aβ plaques. In contrast, adoptive transfer of Teffs diminished behavioral function and cytokine production. Next, we transiently depleted Treg population using an anti-CD25 antibody (PC61). Depletion of Tregs for four months resulted in a marked aggravation of the spatial learning deficits of six-month-old 3xTg-AD mice. Additionally, it resulted in decreasing glucose metabolism, as assessed by positron emission tomography (PET) with 18F-2 fluoro-2-deoxy-D-glucose ([F-18] FDG) neuroimaging. Importantly, the deposition of Aβ plaques and microglia/macrophage was increased in the hippocampal CA1 and CA3 regions of the Treg depleted 3xTg-AD compared to the vehicle-treated 3xTg-AD group. Our finding suggested that systemic Treg administration ameliorates disease progression and could be an effective Alzheimer's disease treatment.
The long-term surgical results of the MBP without CFL reconstruction for chronic lateral ankle instability were good to excellent in terms of functional, clinical, and radiographic assessments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.