Abstract. The aim of the present study was to investigate the efficacy of dynamic contrast-enhanced magnetic resonance imaging (MRI) in predicting the outcome of using ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation for the treatment of uterine fibroids with T2 hyperintensity under MRI. A total of 131 uterine fibroids from 131 patients that appeared hyperintense under T2-weighted MRI were analyzed. The uterine fibroids were subjectively categorized into slight, irregular or regular enhancement groups, according to pretreatment dynamic contrast-enhanced MRI in the arterial phase within 60 sec after the injection of gadolinium. The non-perfused volume (NPV), which is indicative of successful ablation, was represented as the non-perfused area inside the uterine fibroids on enhanced MRI scans following treatment. Additionally, the treatment duration, treatment efficiency, sonication duration, energy efficiency ratio and any adverse events were recorded. The results indicated that the average NPV ratio for all the treated fibroids was 68.5%, while the average NPV ratios for fibroids with slight, irregular or regular enhancement were 84.7, 70.6 and 57.1%, respectively. Fibroids with regular enhancement were associated with the lowest NPV ratio and the lowest treatment efficiency, but exhibited the highest energy effect ratio and an elevated risk of severe adverse effects. The results of the present study indicate that hyperintense uterine fibroids with slight and irregular enhancement in the arterial phase of dynamic contrast-enhanced MRI are suitable for USgHIFU treatment. By contrast, uterine fibroids with regular enhancement were associated with the lowest treatment efficacy and safety.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.