Surface cleaning using commercial disinfectants, which has recently increased during the coronavirus disease 2019 pandemic, can generate secondary indoor pollutants both in gas and aerosol phases. It can also affect indoor air quality and health, especially for workers repeatedly exposed to disinfectants. Here, we cleaned the floor of a mechanically ventilated office room using a commercial cleaner while concurrently measuring gas-phase precursors, oxidants, radicals, secondary oxidation products, and aerosols in real-time; these were detected within minutes after cleaner application. During cleaning, indoor monoterpene concentrations exceeded outdoor concentrations by two orders of magnitude, increasing the rate of ozonolysis under low (<10 ppb) ozone levels. High number concentrations of freshly nucleated sub–10-nm particles (≥10 5 cm −3 ) resulted in respiratory tract deposited dose rates comparable to or exceeding that of inhalation of vehicle-associated aerosols.
Thymol-based botanical disinfectants have emerged as natural alternatives to traditional chemical disinfectants given their effectiveness as antimicrobial pesticides and ability to inactivate SARS-CoV-2. This study investigates the impact of botanical disinfectants on indoor air chemistry and human exposure. Controlled surface disinfection experiments were conducted in a mechanically ventilated zero-energy tiny house laboratory. Volatile organic compounds (VOCs) and aerosol size distributions were measured in real-time (1 Hz) with a proton transfer reaction time-of-flight mass spectrometer and a highresolution electrical low-pressure impactor, respectively. Botanical disinfectant spray and wipe products drove sudden changes in the chemical composition of indoor air. Mixing ratios of monoterpenes (C 10 H 16 ) and monoterpenoids (C 10 H 14 O, C 10 H 16 O, C 10 H 18 O, and C 10 H 20 O) increased suddenly during the disinfection events (10 −1 to 10 2 ppb) and exhibited volatility-dependent temporal emission profiles. VOC emission factors ranged from 10 0 to 10 4 μg g −1 , and thymol intake fractions ranged from 6 to 7 × 10 3 ppm. Rapid new particle formation events were observed due to ozonolysis of monoterpenes and monoterpenoids, increasing sub-100 nm particle number concentrations by 10 4 to 10 5 cm −3 . Botanical disinfectant sprays initiated multiphase inhalation exposure to VOCs, secondary organic aerosol, and sub-10 μm droplets, with large deposited doses in each respiratory tract region associated with the latter two.
The integration of Internet of Things (IoT)-enabled sensors and building energy management systems (BEMS) into smart buildings offers a platform for real-time monitoring of myriad factors that shape indoor air quality. This study explores the application of building energy and smart thermostat data to evaluate indoor ultrafine particle dynamics (UFP, diameter ≤ 100 nm). A new framework is developed whereby a cloud-based BEMS and smart thermostats are integrated with real time UFP sensing and a material balance model to characterize UFP source and loss processes. The data-driven framework was evaluated through a field campaign conducted in an occupied net-zero energy buildingthe Purdue Retrofit Net-zero: Energy, Water, and Waste (ReNEWW) House. Indoor UFP source events were identified through time-resolved electrical kitchen appliance energy use profiles derived from BEMS data. This enabled determination of kitchen appliance-resolved UFP source rates and time-averaged concentrations and size distributions. BEMS and smart thermostat data were used to identify the operational mode and runtime profiles of the air handling unit and energy recovery ventilator, from which UFP source and loss rates were estimated for each mode. The framework demonstrates that equipment-level energy use data can be used to understand how occupant activities and building systems affect indoor air quality.
NCl3 is formed as a disinfection byproduct in chlorinated swimming pools and can partition between the liquid and gas phases. Exposure to gas-phase NCl3 has been linked to asthma and can irritate the eyes and respiratory airways, thereby affecting the health and athletic performance of swimmers. This study involved an investigation of the spatiotemporal dynamics of gas-phase NCl3 in an aquatic center during a collegiate swim meet. Real-time (up to 1 Hz) measurements of gas-phase NCl3 were made via a novel on-line derivatization cavity ring-down spectrometer and a proton transfer reaction time-of-flight mass spectrometer. Significant temporal variations in gas-phase NCl3 and CO2 concentrations were observed across varying time scales, from seconds to hours. Gas-phase NCl3 concentrations increased with the number of active swimmers due to swimming-enhanced liquid-to-gas transfer of NCl3, with peak concentrations between 116 and 226 ppb. Strong correlations between concentrations of gas-phase NCl3 with concentrations of CO2 and water (relative humidity) were found and attributed to similar features in their physical transport processes in pool air. A vertical gradient in gas-phase NCl3 concentrations was periodically observed above the water surface, demonstrating that swimmers can be exposed to elevated levels of NCl3 beyond those measured in the bulk air.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.