Abstract. A system based on incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) has been developed for simultaneous measurement of nitrogen dioxide (NO2), glyoxal (GLY), and methylglyoxal (MGLY). In this system, the measured light absorption at around 460 nm is spectrally resolved. The concentration of absorbers is determined from a multicomponent fit. At an integration time of 100 s, the measurement sensitivity (2σ) for NO2, GLY, and MGLY is 18, 30, and 100 ppt, respectively. The measurement uncertainty, which mainly originates from path length calibration, sampling loss, and uncertainty of absorption cross sections is estimated to be 8 % for NO2, 8 % for GLY, and 16 % for MGLY. When deploying the instrument during field observations, we found significant influence of NO2 on the spectra fitting for retrieving GLY and MGLY concentrations, which is caused by the fact that NO2 has a higher absorption cross section and higher ambient concentration. In order to minimize such an effect, a NO2 photolytic convertor (NPC), which removes sampled NO2 at an efficiency of 76 %, was integrated on the IBBCEAS system. Since sampled GLY and MGLY are mostly (≥95 %) conserved after passing through the NPC, the quality of the spectra fitting and the measurement accuracy of ambient GLY and MGLY under NO2-rich environments could be improved.
Abstract. The first OH and HO2 radical observation in Yangtze River Delta, one of the four major urban agglomerations in China, was carried out at a suburban site (Taizhou) in summer 2018 from May to June, aiming to elucidate the atmospheric oxidation capacity in this region. The maximum diurnal averaged OH and HO2 concentrations were 1.0×107 and 1.1×109 cm−3, respectively, which were the second highest HOx (sum of OH and HO2) radical concentrations observed in China. HONO photolysis was the dominant radical primary source, accounting for 42 % of the total radical initiation rate. Other contributions were from carbonyl photolysis (including HCHO, 24 %), O3 photolysis (17 %), alkene ozonolysis (14 %), and NO3 oxidation (3 %). A chemical box model based on the RACM2-LIM1 mechanism could generally reproduce the observed HOx radicals, but systematic discrepancy remained in the afternoon for the OH radical, when the NO mixing ratio was less than 0.3 ppb. An additional recycling mechanism equivalent to 100 ppt NO was capable to fill the gap. The sum of monoterpenes was on average up to 0.4 ppb during daytime, which was all allocated to α-pinene in the base model. A sensitivity test without monoterpene input showed the modeled OH and HO2 concentrations would increase by 7 % and 4 %, respectively, but modeled RO2 concentration would significantly decrease by 23 %, indicating that monoterpene was an important precursor of RO2 radicals in this study. Consequently, the daily integrated net ozone production would reduce by 6.3 ppb without monoterpene input, proving the significant role of monoterpene in the photochemical O3 production in this study. In addition, the generally good agreement between observed and modeled HOx concentrations suggested no significant HO2 heterogeneous uptake process during this campaign. Incorporation of HO2 heterogeneous uptake process would worsen the agreement between HOx radical observation and simulation, and the discrepancy would be beyond the combined measurement–model uncertainties using an effective uptake coefficient of 0.2. Finally, the ozone production efficiency (OPE) was only 1.7 in this study, a few folds lower than other studies in (sub)urban environments. The low OPE indicated a slow radical propagation rate and short chain length. As a consequence, ozone formation was suppressed by the low NO concentration in this study.
Formaldehyde (HCHO) is the most abundant atmospheric carbonyl compound and plays an important role in the troposphere. However, HCHO detection via traditional incoherent broadband cavity enhanced absorption spectroscopy (IBBCEAS) is limited by short optical path lengths and weak light intensity. Thus, a new light-emitting diode (LED)-based IBBCEAS was developed herein to measure HCHO in ambient air. Two LEDs (325 and 340 nm) coupled by a Y-type fiber bundle were used as an IBBCEAS light source, which provided both high light intensity and a wide spectral fitting range. The reflectivity of the two cavity mirrors used herein was 0.99965 (1 − reflectivity = 350 ppm loss) at 350 nm, which corresponded with an effective optical path length of 2.15 km within a 0.84 m cavity. At an integration time of 30 s, the measurement precision (1σ) for HCHO was 380 parts per trillion volume (pptv), and the corresponding uncertainty was 8.3%. The instrument was successfully deployed for the first time in a field campaign and delivered results that correlated well with those of a commercial wet-chemical instrument based on Hantzsch fluorimetry (R 2 = 0.769). The combined light source based on a Y-type fiber bundle overcomes the difficulty of measuring ambient HCHO via IBBCEAS in near-ultraviolet range, which may extend IBBCEAS technology to measure other atmospheric trace gases with high precision.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.