Face mask ventilation of apnoeic neonates is an essential skill. However, many non-paediatric healthcare personnel (HCP) in high-resource childbirth facilities receive little hands-on real-life practice. Simulation training aims to bridge this gap by enabling skill acquisition and maintenance. Success may rely on how closely a simulator mimics the clinical conditions faced by HCPs during neonatal resuscitation. Using a novel, low-cost, high-fidelity simulator designed to train newborn ventilation skills, we compared objective measures of ventilation derived from the new manikin and from real newborns, both ventilated by the same group of experienced paediatricians. Simulated and clinical ventilation sequences were paired according to similar duration of ventilation required to achieve success. We found consistencies between manikin and neonatal positive pressure ventilation (PPV) in generated peak inflating pressure (PIP), mask leak and comparable expired tidal volume (eVT), but positive end-expiratory pressure (PEEP) was lower in manikin ventilation. Correlations between PIP, eVT and leak followed a consistent pattern for manikin and neonatal PPV, with a negative relationship between eVT and leak being the only significant correlation. Airway obstruction occurred with the same frequency in the manikin and newborns. These findings support the fidelity of the manikin in simulating clinical conditions encountered during real newborn ventilation. Two limitations of the simulator provide focus for further improvements.
Aim: T-piece resuscitators are commonly used for respiratory support during newborn resuscitation. This study aimed to describe delivered pressures and tidal volumes when resuscitating term newborns immediately after birth, using the NeoPu T-piece resuscitator.
Positive pressure ventilation of the non-breathing newborn is a critical and time-sensitive intervention, considered to be the cornerstone of resuscitation. Many healthcare providers working in delivery units in high-resource settings have little opportunity to practise this skill in real life, affecting their performance when called upon to resuscitate a newborn. Low-dose, high-frequency simulation training has shown promise in low-resource settings, improving ventilation performance and changing practice in the clinical situation. We performed a randomised controlled study of low-dose, high-frequency simulation training for maintenance of ventilation competence in a multidisciplinary staff in a busy teaching hospital in Norway. We hypothesised that participants training according to a low-dose, high-frequency protocol would perform better than those training as they wished. Our results did not support this, although the majority of protocol participants were unable to achieve training targets. Subgroup analysis comparing no training to at least monthly training did identify a clear benefit to regular simulation practice. Simulated ventilation competence improved significantly for all participants over the course of the study. We conclude that frequent, short, simulation-based training can foster and maintain newborn ventilation skills in a multidisciplinary delivery unit staff in a high-resource setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.