Acquired cataract and cognitive impairment are both common age related problems, and ophthalmologists are increasingly likely to encounter patients who have both. Dementia types which display early visuo-perceptual impairment may present first to ophthalmology services. When these patients have coexisting cataract it may be difficult to distinguish visual complaints due to cataract from those due to dementia.The interaction between visual impairment due to cataract, and neurodegenerative disorders affecting the central visual pathways, is not fully understood. Visual impairment due to cataract may stress impaired attentional mechanisms, and cataract extraction may improve cognitive performance in some patients with early cognitive impairment; however the benefits of cataract surgery in established dementia are less clear. Here we review the literature on this subject and consider the implications for practice.
PurposeTo determine the safety and effectiveness of orbital decompression for thyroid eye disease (TED) in our unit. To put this in the context of previously published literature.Patients and methodsA retrospective case review of all patients undergoing orbital decompression for TED under the care of one orbital surgeon (SMS) between January 2009 and December 2015. A systematic literature review of orbital decompression for TED.ResultsWithin the reviewed period, 93 orbits of 55 patients underwent decompression surgery for TED. There were 61 lateral (single) wall decompressions, 17 medial one-and-a-half wall, 11 two-and-a-half wall, 2 balanced two wall, and 2 orbital fat only decompressions. For the lateral (single) wall decompressions, mean reduction in exophthalmometry (95% confidence interval (CI) was 4.2 mm (3.7-4.8), for the medial one-and-a-half walls it was 2.9 mm (2.1-3.7), and for the two-and-a-half walls it was 7.6 mm (5.8-9.4). The most common complications were temporary postoperative numbness (29% of lateral decompressions, 17% of other bony decompressions, OR 0.50, 95% CI 0.12-2.11) and new postoperative diplopia (9% of lateral decompressions, 39% of other bony decompressions, OR 6.8, 95% CI 1. 5-30.9). Systematic literature searching showed reduction in exophthalmometry for lateral wall surgery of 3.6-4.8 mm, with new diplopia 0-38% and postoperative numbness 12-50%. For other bony decompressions, reduction in exophthalmometry was 2.5-8.0 mm with new diplopia 0-45% and postoperative numbness up to 52%.ConclusionDiffering approaches to orbital decompression exist. If the correct type of surgery is chosen, then safe, adequate surgical outcomes can be achieved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.