Background Coagulation abnormalities in COVID-19 patients have not been addressed in depth. Objective To perform a longitudinal evaluation of coagulation profile of patients admitted to the ICU with COVID-19. Methods Conventional coagulation tests, rotational thromboelastometry (ROTEM), platelet function, fibrinolysis, antithrombin, protein C and S were measured at days 0, 1, 3, 7 and 14. Based on median total maximum SOFA score, patients were divided in two groups: SOFA ≤ 10 and SOFA > 10. Results Thirty patients were studied. Some conventional coagulation tests, as aPTT, PT and INR remained unchanged during the study period, while alterations on others coagulation laboratory tests were detected. Fibrinogen levels were increased in both groups. ROTEM maximum clot firmness increased in both groups from Day 0 to Day 14. Moreover, ROTEM–FIBTEM maximum clot firmness was high in both groups, with a slight decrease from day 0 to day 14 in group SOFA ≤ 10 and a slight increase during the same period in group SOFA > 10. Fibrinolysis was low and decreased over time in all groups, with the most pronounced decrease observed in INTEM maximum lysis in group SOFA > 10. Also, D-dimer plasma levels were higher than normal reference range in both groups and free protein S plasma levels were low in both groups at baseline and increased over time, Finally, patients in group SOFA > 10 had lower plasminogen levels and Protein C than patients with SOFA <10, which may represent less fibrinolysis activity during a state of hypercoagulability. Conclusion COVID-19 patients have a pronounced hypercoagulability state, characterized by impaired endogenous anticoagulation and decreased fibrinolysis. The magnitude of coagulation abnormalities seems to correlate with the severity of organ dysfunction. The hypercoagulability state of COVID-19 patients was not only detected by ROTEM but it much more complex, where changes were observed on the fibrinolytic and endogenous anticoagulation system.
Point-of-Care Testing (POCT) has been highlighted in the health care sector in recent decades. On the other hand, due to its low demand, POCT is at a disadvantage compared to conventional equipment, since its cost is inversely proportional to the volume of use. In addition, for the implementation of POCT to succeed, it is essential to rely on the work of a multidisciplinary team. The awareness of health professionals of the importance of each step is perhaps the critical success factor. The trend towards the continuous advancement of the use of POCT and the great potential of its contributions reinforce the need to implement quality management tools, including performance indicators, to ensure their results. This review presents some advantages and disadvantages concerning POCT and the real need to use it. A worldwide call for the availability of easy-to-use health technologies that are increasingly closer to the final user is one of the main reasons for this focus.
BackgroundDengue virus infection (DVI) is a prevalent and potentially fatal viral disease associated with coagulopathy. So far, the coagulation profile of DVI patients with thrombocytopenia has not been assessed through a viscoelastic test such as rotational thromboelastometry. We aimed to describe the prevalence and characteristics of coagulation abnormalities in dengue fever outpatients with thrombocytopenia, addressed by both rotational thromboelastometry and conventional coagulation tests.MethodsThis was a cross-sectional study conducted between April 6th and May 5th 2015 in São Paulo, Brazil during a dengue outbreak. Thromboelastometry (ROTEM®) and the conventional coagulation tests prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), thrombin time (TT), platelet count and fibrinogen levels were performed in 53 patients with DVI and thrombocytopenia.ResultsDespite a median interquartile range (IQR) platelet count of 77 (63–88) x 109/L in DVI patients, conventional coagulation tests and plasma fibrinogen levels were within the normal range. Subjects demonstrated hypocoagulability in 71.7% (38/53) in INTEM and 54.7% (29/53) in EXTEM DVI patients. FIBTEM analyses detected only 5.7% (3/53) with hypocoagulability among this population. The median (IQR) clotting time (CT), clot formation time (CFT) and maximum clot firmness (MCF) on INTEM were, respectively, 177 (160–207) sec, 144 (108–178) sec and 48 (42–52) mm. On EXTEM, median (IQR) CT, CFT and MCF were, respectively, 69 (65–78) sec, 148 (126–198) sec and 49 (44–55) mm. Median (IQR) MCF on FIBTEM was 15 (13–18) mm.ConclusionThromboelastometry impairment is highly prevalent in DVI patients with thrombocytopenia, particularly in INTEM and EXTEM analyses, while standard coagulation tests are normal in this setting. Clinical implications remain to be established.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.