The impact of antithrombotic regimen and platelet inhibition extent on subclinical leaflet thrombosis (SLT) detected by cardiac multidetector computed tomography (MDCT) after transcatheter aortic valve replacement (TAVR) is not well established. Hypoattenuation affecting motion (HAM) has been proposed as a surrogate marker of SLT, and is characterized by hypoattenuated leaflet thickening (HALT) and concomitant reduction in leaflet motion (RELM). We sought to investigate (i) the prevalence of HAM and HALT after TAVR detected by MDCT, (ii) the predictors of SLT, (iii) the impact of oral anticoagulant (OAC) and platelet inhibition extent assessed by platelet reactivity index vasodilator stimulated phosphoprotein (PRI-VASP) and closure time adenosine diphosphate (CT-ADP) on SLT. Of 187 consecutive patients who underwent TAVR from 1 August 2017 to 31 March 2018, 90 of them had cardiac CT at relevant follow-up. Clinical, biological, echocardiographic, procedural characteristics and treatments were collected before, at discharge, and 1 year after TAVR. P2Y12 platelet inhibition extent and primary haemostasis disorders were investigated using platelet PRI-VASP and CT-ADP point-of-care assays. Eighty-five post-TAVR CTs out of 90 were ranked for clarity and assessed with sufficient diagnostic quality. HAM was evidenced in 13 patients (15.3%) and HALT in 30 patients (35%). Procedural characteristics, including aortic valve calcium score, annulus size, or procedural heparin regimens, were equivalent between groups. Likewise, no impact of P2Y12 inhibition (PRI-VASP) nor primary haemostasis disorders (CT-ADP) on SLT could be evidenced. No impact of SLT on valve deterioration evaluated by transthoracic echocardiography (TTE) and clinical events could be established at 12 months follow-up. By multivariate analysis, lack of oral anticoagulant therapy at discharge (HR 12.130 CI 95% (1.394–150.582); p = 0.028) and higher haemoglobin levels were evidenced as the sole independent predictors of SLT. In four patients with HAM, MDCT follow-up was obtained after initiation of OAC therapy and showed a complete regression of HAM. SLT was evidenced in a sizeable proportion of patients treated by TAVR and was mainly determined by the lack of oral anticoagulant therapy. Conversely, no impact of platelet inhibition extent on SLT could be evidenced.
Aims Cardiovascular disease has been recognized as a major determinant of coronavirus disease 2019 (COVID‐19) vulnerability and severity. Angiotensin‐converting enzyme (ACE) 2 is a functional receptor for severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) and is up‐regulated in patients with heart failure. We sought to examine the potential association between reduced left ventricular ejection fraction (LVEF) and the susceptibility to SARS‐CoV‐2 infection. Methods and results Of the 1162 patients with acute coronary syndrome (ACS) who underwent percutaneous coronary intervention between February 2014 and October 2018, we enrolled 889 patients with available clinical follow‐up data. Follow‐up was conducted by telephone interviews 1 month after the start of the French lockdown which began on 17 March 2020. Patients were divided into two groups according to LVEF <40% (reduced LVEF) ( n = 91) or ≥40% (moderately reduced + preserved LVEF) ( n = 798). The incidence of COVID‐19‐related hospitalization or death was significantly higher in the reduced LVEF group as compared with the moderately reduced + preserved LVEF group (9% vs. 1%, P < 0.001). No association was found between discontinuation of ACE‐inhibitor or angiotensin‐receptor blockers and COVID‐19 test positivity. By multivariate logistic regression analysis, reduced LVEF was an independent predictor of COVID‐19 hospitalization or death (odds ratio: 6.91, 95% confidence interval: 2.60 to 18.35, P < 0.001). Conclusions In a large cohort of patients with previous ACS, reduced LVEF was associated with increased susceptibility to COVID‐19. Aggressive COVID‐19 testing and therapeutic strategies may be considered for patient with impaired heart function.
Background Electrocardiographic strain pattern (ESP) has recently been associated with increased adverse outcome in aortic stenosis and after surgical aortic valve replacement. Our study sought to determine the impact and incremental value of ESP pattern in predicting adverse outcome after transcatheter aortic valve replacement. Methods and Results A total of 585 patients with severe aortic stenosis (mean age, 83±7 years; men, 39.8%) were enrolled for transcatheter aortic valve replacement from November 2012 to May 2018. ESP was defined as ≥1‐mm concave down‐sloping ST‐segment depression and asymmetrical T‐wave inversion in the lateral leads. The primary end points of the study were all‐cause mortality, rehospitalization for heart failure, myocardial infarction, and stroke. A total of 178 (30.4%) patients were excluded because of left bundle‐branch block (n=103) or right bundle‐branch block (n=75). Among the 407 remaining patients, 106 had ESP (26.04%). At a median follow‐up of 20.00 months (11.70–29.42 months), no impact of electric strain on overall and cardiac death could be established. By contrast, incidence of rehospitalization for heart failure was significantly higher (33/106 [31.1%] versus 33/301 [11%]; P <0.001) in patients with ESP. By multivariate analyses, ESP remained a strong predictor of rehospitalization for heart failure (hazard ratio, 2.75 [95% CI, 1.61–4.67]; P <0.001). Conclusions In patients with aortic stenosis who were eligible for transcatheter aortic valve replacement, ESP is frequent and associated with an increased risk of postinterventional heart failure regardless of preoperative left ventricular hypertrophy. ESP represents an easy, objective, reliable, and low‐cost tool to identify patients who may benefit from intensified postinterventional follow‐up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.