Patient preference of lower limb prosthesis behavior informally guides clinical decision making, and may become increasingly important for tuning new robotic prostheses. However, the processes for quantifying preference are still being developed, and the strengths and weaknesses of preference are not adequately understood. The present study sought to characterize the reliability (consistency) of patient preference of alignment during level-ground walking, and determine the patient-preferred ankle angle for ascent and descent of a 10° ramp, with implications for the design and control of robotic prostheses. Seven subjects with transtibial amputation walked over level ground, and ascended and descended a 10° ramp on a semi-active prosthetic ankle capable of unweighted repositioning in dorsiflexion and plantarflexion. Preferred ankle angle was measured with an adaptive forced-choice psychophysics paradigm, in which subjects walked on a randomized static ankle angle and reported whether they would prefer the ankle to be dorsiflexed or plantarflexed. Subjects had reliable preferences for alignment during level-ground walking, with deviations of 1.5° from preference resulting in an 84% response rate preferring changes toward the preference. Relative to level walking, subjects preferred 7.8° (SD: 4.8°) of dorsiflexion during ramp ascent, and 5.3° (SD: 3.8°) plantarflexion during ramp descent. As the ankle angle better matched the ramp angle, socket pressures and tibial progression (shank pitch) both more closely mirrored those during level walking. These findings provide baseline behaviors for prosthetic ankles capable of adapting to slopes based on patient preference, and provide strong evidence that people with transtibial amputation can finely perceive ankle alignment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.