Renal artery stenting has been established as the primary form of renal artery stenosis revascularization procedure. The no-touch technique is proposed in order to avoid renal artery injury and atheroembolism during renal artery stenting. We describe a modification of the no-touch technique by using an over-the-wire (OTW) balloon or a Quickcross 0.014′′ catheter with a 0.014′′ coronary wire inside, instead of the rigid 0.035′′ J wire. The reported technique, while it prevents direct contact of the guiding catheter with the aortic wall, at the same time it allows for a closer contact with the renal arterial ostium and a more favorable guiding catheter orientation, compared to what is achieved with the use of the more rigid 0.035′′ J wire, thus improving visualization, reducing the amount of contrast required, and potentially decreasing complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.