The level of acetate-group surface segregation in poly(vinyl alcohol-co-vinyl acetate) (PVA−PVAc) films was found to depend markedly on the functional group distribution along the backbone (blockiness). PVA−PVAc polymers with both random and blocky distributions were prepared at levels between 2 and 12 mol % acetate and cast into films from aqueous solution. Films from polymers with blocky distributions showed significantly higher levels of acetate at the surface than in the bulk, while polymers with random distributions of acetate functionality exhibited little or no surface segregation. The level of acetate surface segregation was determined by both X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectroscopy (ToF-SIMS). Blocky PVA−PVAc films containing 4 mol % were seen to have approximately 40 mol % PVAc at the outermost surface by XPS at low take-off angle. Bulk acetate levels and acetate group distributions were determined by NMR. Variations in the weight average molecular weight (M w) between 40k and 155k, modifying the casting solvent, or annealing the films above T g did not effect the level of surface segregation, suggesting that the segregation is not simply a kinetic phenomenon.
Comment on ''The dielectric relaxation studies on poly(vinyl acetate)''A series of solvent cast poly (vinyl alcohol-co-vinyl acetate) (PY A/PY Ac) copolymer films with PYAc concentrations ranging from 0% to 12% have been characterized with bulk nuclear magnetic resonance and surface [variable angle x-ray photoelectron spectroscopy (XPS) and time-of-flight (TOF) secondary ion mass spectroscopy (SIMS)] analytical techniques. PYAc was observed to preferentially segregate to the top most surface region, and despite variations in the bulk levels of PY Ac the surface is composed of approximately 40% PY Ac. The data suggests segregation is driven by the methyl groups of the acetate functionality and can be predicted based on the minimization of surface energy. TOF-SIMS data aided XPS peak assignments and observed minute manufacturing impurities (Na, K, Ca, and Si) undetected by XPS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.