In 1995 the National Institute for Occupational Safety and Health issued new regulations for nonpowered particulate respirators (42 CFR Part 84). A new filter certification system also was created. Among the new particulate respirators that have entered the market, the N95 respirator is the most commonly used in industrial and health care environments. The filtration efficiencies of unloaded N95 particulate respirators have been compared with those of dust/mist (DM) and dust/fume/mist (DFM) respirators certified under the former regulations (30 CFR Part 11). Through laboratory tests with NaCl certification aerosols and measurements with particle-size spectrometers, N95 respirators were found to have higher filtration efficiencies than DM and DFM respirators and noncertified surgical masks. N95 respirators made by different companies were found to have different filtration efficiencies for the most penetrating particle size (0.1 to 0.3 micron), but all were at least 95% efficient at that size for NaCl particles. Above the most penetrating particle size the filtration efficiency increases with size; it reaches approximately 99.5% or higher at about 0.75 micron. Tests with bacteria of size and shape similar to Mycobacterium tuberculosis also showed filtration efficiencies of 99.5% or higher. Experimental data were used to calculate the aerosol mass concentrations inside the respirator when worn in representative work environments. The penetrated mass fractions, in the absence of face leakage, ranged from 0.02% for large particle distributions to 1.8% for submicrometer-size welding fumes. Thus, N95 respirators provide excellent protection against airborne particles when there is a good face seal.
Microbial stress due to the impaction of microorganisms onto an agar collection surface was studied experimentally. The relative recovery rates of aerosolized Pseudomonas fluorescens and Micrococcus luteus were determined as a function of the impaction velocity by using a moving agar slide impactor operating over a flow rate range from 3.8 to 40 liters/min yielding impaction velocities from 24 to 250 m/s. As a reference, the sixth stage of the Andersen Six-Stage Viable Particle Sizing Sampler was used at its operating flow rate of 28.3 liters/min (24 m/s). At a collection efficiency of close to 100% for the agar slide impactor, an increase in sampling flow rate and, therefore, in impaction velocity produced a significant decline in the percentage of microorganisms recovered. Conversely, when the collection efficiency was less than 100%, greater recovery and lower injury rates occurred. The highest relative rate of recovery (approximately 51% for P. fluorescens and approximately 62% for M. luteus) was obtained on the complete (Trypticase soy agar) medium at 40 and 24 m/s (6.4 and 3.8 liters/min), respectively. M. luteus demonstrated less damage than P. fluorescens, suggesting the hardy nature of the gram-positive strain versus that of the gram-negative microorganism. Comparison of results from the agar slide and Andersen impactors at the same sampling velocity showed that recovery and injury due to collection depends not only on the magnitude of the impaction velocity but also on the degree to which the microorganisms may be embedded in the collection medium. Impaction velocity, characterized by the sampler's operating flow rate and inlet design, is unique for each sampling device. The resulting impaction stress influences the recovery and injury of collected microorganisms and ultimately affects the measurement data for colony enumeration. This can be one of the most important reasons for variations that occur when using different sampling devices to measure bioaerosols from the same environment.
Bacterial agents and cell components can be spread as bioaerosols, producing infections and asthmatic problems. This study compares four methods for the detection and enumeration of aerosolized bacteria collected in an AGI-30 impinger. Changes in the total and viable concentrations of Pseudomonas fluorescens in the collection fluid with respect to time of impingement were determined. Two direct microscopic methods (acridine orange and BacLight) and aerodynamic aerosol-size spectrometry (Aerosizer) were employed to measure the total bacterial cell concentrations in the impinger collection fluid and the air, respectively. These data were compared with plate counts on selective (MacConkey agar) and nonselective (Trypticase soy agar) media, and the percentages of culturable cells in the collection fluid and the bacterial injury response to the impingement process were determined. The bacterial collection rate was found to be relatively unchanged during 60 min of impingement. The aerosol measurements indicated an increased amount of cell fragments upstream of the impinger due to continuous bacterial nebulization. Some of the bacterial clusters, present in the air upstream of the impinger, deagglomerated during impingement, thus increasing the total bacterial count by both direct microscopic methods. The BacLight staining technique was also used to determine the changes in viable bacterial concentration during the impingement process. The percentage of viable bacteria, determined as a ratio of BacLight live to total counts was only 20% after 60 min of sampling. High counts on Trypticase soy agar indicated that most of the injured cells could recover. On the other hand, the counts from the MacConkey agar were very low, indicating that most of the cells were structurally damaged in the impinger. The comparison of data on the percentage of injured bacteria obtained by the traditional plate count with the data on percentage of nonviable bacteria obtained by the BacLight method showed good agreement.
ABSTRACT. The collection efficiency of liquid impingers was studied experimentally as a function of the sampling flow rate with test particles in the bacterial size range. Three impingers were tested: two All-Glass Impingers (AGI-4 and AGI-301, widely used for bioaerosol sampling, and a newly developed slot impinger. The aerosol particles were generated by a Collison nebulizer, and an Aerosizer was used to measure the particle concentrations and size distributions upstream and downstream of each impinger. The effect of the air pressure drop across the impinger on the Aerosizer performance was investigated, and the particle measurement system was modified and calibrated accordingly. While inertial impaction is the dominant particle removal mechanism in impingers, particle bounce and reaerosolization were also found to have significant effects on the impinger collection characteristics. At relatively high flow rates and low levels of collection fluid (corresponding to the collection fluid level after evaporation of most of the liquid during prolonged impingement), the liquid under the impinger jet was observed to be removed by the air pressure and pushed against the container's walls. Particles, such as bacterial or fungal spores, may thus bounce from the bottom of the collection vessel and escape with the effluentair flow or may impact sideways into the liquid that was previously pushed against the walls. It was found that such particle bounce may significantly reduce the collection efficiency of impingers containing a small amount of liquid. When the impingers were operated at a high level of collection fluid and sufficiently high sampling flow rates, it was observed that the bubbles, rising through the liquid, entrained previously collected particles and created new aerosols by bursting at the liquidair surface. Such particle reaerosolization was also found to reduce the impinger collection efficiency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.