The high explosives trinitrotoluene, nitroglycerine, pentaerythritol tetranitrate and hexahydro-1,3,5-trinitro-1,3,5-triazine are efficiently ionised under negative ion atmospheric pressure chemical ionisation (APCI) conditions. The limit of detection is improved, in some cases by several orders of magnitude, by complexation with chlorine demonstrating this to be a highly suitable method for enhancing the detection capabilities for explosives. The spectra produced from introduction of the analytes in a liquid matrix, with and without chlorine present, contain a number of ions that arise through secondary processes including breakdown and adduct formation. Sample introduction into an APCI source in air, via a heated-plate inlet with a supplementary feed of dichloromethane, produces improved response for the chloride adducts of the analytes and minimises their decomposition during analysis. The tandem mass spectra produced from the chloride adducts are simple. Optimisation of the trapping parameters of the ion trap detector enhances selected transitions, yields highly reproducible spectra and improves the limits of detection for MS/MS analysis.
The detection of explosives is of great importance, as is the need for sensitive, reliable techniques that require little or no sample preparation and short run times for high throughput analysis. In this work, a novel ionisation source is presented based on a dielectric barrier discharge (DBD). This not only affects desorption and ionisation but also forms an ionic wind, providing mass transportation of ions towards the mass spectrometer. Furthermore, the design incorporates 2 asymmetric alumina sheets, each containing 3 DBDs, so that a large surface area can be analysed. The DBD operates in ambient air, overcoming the limitation of other plasma-based techniques which typically analyse smaller surface areas and require solvents or gases. A range of explosives across 4 different functional groups was analysed using the DBD with low limits of detection for cyclotrimethylene trinitramine (RDX) (100 pg), pentaerythritol trinitrate (PETN) (100 pg), hexamethylene triperoxide diamide (HMTD) (1 ng), and trinitrotoluene (TNT) (5 ng). Detection was achieved without any sample preparation or the addition of reagents to facilitate adduct formation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.